Show simple item record

Acoustic Bubble Removal to Enhance SWL Efficacy at High Shock Rate: An In Vitro Study

dc.contributor.authorDuryea, Alexander P.
dc.contributor.authorRoberts, William W.
dc.contributor.authorCain, Charles A.
dc.contributor.authorTamaddoni, Hedieh A.
dc.contributor.authorHall, Timothy L.
dc.date.accessioned2017-12-19T21:18:12Z
dc.date.available2017-12-19T21:18:12Z
dc.date.issued2013-08-19
dc.identifier.citationDuryea, Alexander P.; Roberts, William W.; Cain, Charles A.; Tamaddoni, Hedieh A.; Hall, Timothy L. (2013). "Acoustic Bubble Removal to Enhance SWL Efficacy at High Shock Rate: An In Vitro Study." Journal of Endourology 28 (1): 90-95.
dc.identifier.issn0892-7790
dc.identifier.urihttps://hdl.handle.net/2027.42/140375
dc.description.abstractRate-dependent efficacy has been extensively documented in shock wave lithotripsy (SWL) stone comminution, with shock waves (SWs) delivered at a low rate producing more efficient fragmentation in comparison to those delivered at high rates. Cavitation is postulated to be the primary source underlying this rate phenomenon. Residual bubble nuclei that persist along the axis of SW propagation can drastically attenuate the waveform's negative phase, decreasing the energy which is ultimately delivered to the stone and compromising comminution. The effect is more pronounced at high rates, as residual nuclei have less time to passively dissolve between successive shocks. In this study, we investigate a means of actively removing such nuclei from the field using a low-amplitude acoustic pulse designed to stimulate their aggregation and subsequent coalescence. To test the efficacy of this bubble removal scheme, model kidney stones were treated in vitro using a research electrohydraulic lithotripter. SWL was applied at rates of 120, 60, or 30?SW/min with or without the incorporation of bubble removal pulses. Optical images displaying the extent of cavitation in the vicinity of the stone were also collected for each treatment. Results show that bubble removal pulses drastically enhance the efficacy of stone comminution at the higher rates tested (120 and 60?SW/min), while optical images show a corresponding reduction in bubble excitation along the SW axis when bubble removal pulses are incorporated. At the lower rate of 30?SW/min, no difference in stone comminution or bubble excitation was detected with the addition of bubble removal pulses, suggesting that remnant nuclei had sufficient time for more complete dissolution. These results corroborate previous work regarding the role of cavitation in rate-dependent SWL efficacy, and suggest that the effect can be mitigated via appropriate control of the cavitation environment surrounding the stone.
dc.publisherMary Ann Liebert, Inc., publishers
dc.titleAcoustic Bubble Removal to Enhance SWL Efficacy at High Shock Rate: An In Vitro Study
dc.typeArticle
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/140375/1/end.2013.0313.pdf
dc.identifier.doi10.1089/end.2013.0313
dc.identifier.sourceJournal of Endourology
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.