Analysis of the Occlusal Stress Transmitted to the Inferior Alveolar Nerve by an Osseointegrated Threaded Fixture

dc.contributor.authorSammartino, G.
dc.contributor.authorMarenzi, G.
dc.contributor.authorCitarella, R.
dc.contributor.authorCiccarelli, R.
dc.contributor.authorWang, H‐l
dc.date.accessioned2018-02-05T16:27:09Z
dc.date.available2018-02-05T16:27:09Z
dc.date.issued2008-09
dc.identifier.citationSammartino, G.; Marenzi, G.; Citarella, R.; Ciccarelli, R.; Wang, H‐l (2008). "Analysis of the Occlusal Stress Transmitted to the Inferior Alveolar Nerve by an Osseointegrated Threaded Fixture." Journal of Periodontology 79(9): 1735-1744.
dc.identifier.issn0022-3492
dc.identifier.issn1943-3670
dc.identifier.urihttps://hdl.handle.net/2027.42/141079
dc.publisherAmerican Academy of Periodontology
dc.publisherWiley Periodicals, Inc.
dc.subject.otherinferior alveolar nerve
dc.subject.otherDental implants
dc.titleAnalysis of the Occlusal Stress Transmitted to the Inferior Alveolar Nerve by an Osseointegrated Threaded Fixture
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelDentistry
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Periodontics and Oral Medicine, University of Michigan, Ann Arbor, MI.
dc.contributor.affiliationotherDepartment of Radiology and Radiotherapy, University of Naples â Federico II.â
dc.contributor.affiliationotherDepartment of Mechanical Engineering, University of Salerno, Fisciano, Italy.
dc.contributor.affiliationotherSection of Oral Surgery, Department of Odontostomatological and Maxillofacial Sciences, University of Naples â Federico II,â Naples, Italy.
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/141079/1/jper1735.pdf
dc.identifier.doi10.1902/jop.2008.080030
dc.identifier.sourceJournal of Periodontology
dc.identifier.citedreferenceRho JY, Hobatho MC, Ashman RB. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 1995; 17: 347 â 355.
dc.identifier.citedreferenceKipp DP, Goldstein BH, Weiss WW Jr. Dysesthesia after mandibular third molar surgery: A retrospective study and analysis of 1,377 surgical procedures. J Am Dent Assoc 1980; 100: 185 â 192.
dc.identifier.citedreferenceSimpson HE. Injuries to the inferior dental and mental nerves. J Oral Surg 1958; 16: 300 â 305.
dc.identifier.citedreferenceWalton JN. Altered sensation associated with implants in the anterior mandible: A prospective study. J Prosthet Dent 2000; 83: 443 â 449.
dc.identifier.citedreferenceEllies LG. Altered sensation following mandibular implant surgery: A retrospective study. J Prosthet Dent 1992; 68: 664 â 671.
dc.identifier.citedreferenceWismeijer D, van Waas MA, Vermeeren JI. Patients’ perception of sensory disturbances of the mental nerve before and after implant surgery: A prospective study of 110 patients. Br J Oral Maxillofac Surg 1997; 35: 254 â 259.
dc.identifier.citedreferenceRubenstein JE, Taylor TD. Apical nerve transection resulting from implant placement: A 10â year followâ up report. J Prosthet Dent 1997; 78: 537 â 541.
dc.identifier.citedreferenceEllies LG, Hawker PB. The prevalence of altered sensation associated with implant surgery. Int J Oral Maxillofac Implants 1993; 8: 674 â 679.
dc.identifier.citedreferenceGregg JM. Neuropathic complications of mandibular implant surgery: Review and case presentations. Ann R Australas Coll Dent Surg 2000; 15: 176 â 180.
dc.identifier.citedreferenceBartling R, Freeman K, Kraut RA. The incidence of altered sensation of the mental nerve after mandibular implant placement. J Oral Maxillofac Surg 1999; 57: 1408 â 1410.
dc.identifier.citedreferenceLevitt DS. Apicectomy of an endosseous implant to relieve paresthesia: A case report. Implant Dent 2003; 12: 202 â 205.
dc.identifier.citedreferenceGreenstein G, Tarnow D. The mental foramen and nerve: Clinical and anatomical factors related to dental implant placement: A literature review. J Periodontol 2006; 77: 1933 â 1943.
dc.identifier.citedreferenceSantler G, Kärcher H, Ruda C. Indications and limitations of threeâ dimensional models in cranioâ maxillofacial surgery. J Craniomaxillofac Surg 1998; 26: 11 â 16.
dc.identifier.citedreferenceKois JC. Predictable single tooth periâ implant esthetics: Five diagnostic keys. Compend Contin Educ Dent 2001; 22: 199 â 206.
dc.identifier.citedreferenceHartman F. Introduction to Boundary Elements: Theory and Applications. Berlin: Springerâ Verlag; 1989:154â 215.
dc.identifier.citedreferenceBono B, Cirello A, Geraci D, Pasta A, Cassaro A. FEM model achievement for dental implant characterization. Eur J Implant Prosthodontics 2005; 2: 75 â 85.
dc.identifier.citedreferenceGibbs CH, Mahan PE, Lundeen HC, et al. Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 1981; 46: 443 â 449.
dc.identifier.citedreferenceWirtz DC, Schiffers N, Pandorf T, Radermacher K, Weichert D, Forst R. Critical evaluation of known bone material properties to realize anisotropic FEâ simulation of the proximal femur. J Biomech 2000; 33: 1325 â 1330.
dc.identifier.citedreferenceLee ST, Chen JF. Percutaneous trigeminal ganglion balloon compression for treatment of trigeminal neuralgia â Part 1: Pressure recordings. Surg Neurol 2003; 59: 63 â 67.
dc.identifier.citedreferenceLee ST, Chen JF. Percutaneous trigeminal ganglion balloon compression for treatment of trigeminal neuralgia â Part 2: Results related to compression duration. Surg Neurol 2003; 60: 149 â 154.
dc.identifier.citedreferenceBrown JA, Pilitsis JG. Percutaneous balloon compression for the treatment of trigeminal neuralgia: Results in 56 patients based on balloon compression pressure monitoring. Neurosurg Focus 2005; 18: E10.
dc.identifier.citedreferenceBrown JA, McDaniel MD, Weaver MT. Percutaneous trigeminal nerve compression for treatment of trigeminal neuralgia: Result in 50 patients. Neurosurgery 1993; 32: 570 â 573.
dc.identifier.citedreferenceBrown JA, Hoeflinger B, Long PB, et al. Axon and ganglion cell injury in rabbits after percutaneous trigeminal balloon compression. Neurosurgery 1996; 38: 993 â 1004.
dc.identifier.citedreferenceBelber CJ, Rak RA. Balloon compression rhizolysis in the surgical management of trigeminal neuralgia. Neurosurgery 1987; 20: 908 â 913.
dc.identifier.citedreferenceKopp KC, Koslow AH, Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent 2003; 89: 611 â 615.
dc.identifier.citedreferenceDe Koomen HA. A prosthetic view on vestibuloplasty with free mucosal graft. Int J Oral Surg 1977; 6: 38 â 41.
dc.identifier.citedreferenceBailey PH, Bays RA. Evaluation of longâ term sensory changes following mandibular augmentation procedures. J Oral Maxillofac Surg 1984; 42: 722 â 727.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.