Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease

dc.contributor.authorGoldstein, Stephanie A.
dc.contributor.authorLaPage, Martin J.
dc.contributor.authorDechert, Brynn E.
dc.contributor.authorSerwer, Gerald A.
dc.contributor.authorYu, Sunkyung
dc.contributor.authorLowery, Ray E.
dc.contributor.authorBradley, David J.
dc.date.accessioned2018-06-11T18:00:47Z
dc.date.available2019-07-01T14:52:17Zen
dc.date.issued2018-05
dc.identifier.citationGoldstein, Stephanie A.; LaPage, Martin J.; Dechert, Brynn E.; Serwer, Gerald A.; Yu, Sunkyung; Lowery, Ray E.; Bradley, David J. (2018). "Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease." Congenital Heart Disease 13(3): 413-418.
dc.identifier.issn1747-079X
dc.identifier.issn1747-0803
dc.identifier.urihttps://hdl.handle.net/2027.42/144309
dc.description.abstractObjectiveInappropriate implantable cardioverter defibrillator (ICD) shocks in children and patients with congenital heart disease (CHD) remain a major complication of device therapy, occurring in as many as 50% of children with ICDs. New generation devices include algorithms designed to minimize inappropriate shocks. This study aimed to evaluate the effect of new generation ICDs on the incidence of inappropriate shocks in the pediatric and CHD population.DesignRetrospective study of patients with CHD or under age 25 receiving ICDs between 2000 and 2015. New generation ICDs were defined as those with Medtronic “SmartShock” algorithms.ResultsTwo hundred eight devices were implanted in 146 patients. Rates of inappropriate shocks were similar between diagnoses (P = .71). The rate of inappropriate shock was 15% over median 5.8 years follow‐up. In the 36 patients (25%) with new generation ICDs, the rate of inappropriate shock was 6.3% over 4 years. Comparing old to new generation ICDs, freedom from first inappropriate shock was 90.6% versus 97.1% at 1 year and 80.4% versus 97.1% at 3 years (P = .01). Lead fracture was associated with having inappropriate shock (hazard ratio 8.5, P < .0001), and there was no significant difference between the device groups when lead fractures were excluded. Clinical actions were taken in 69% of patients after initial inappropriate shock (such as medication or program change, system revision, or explant). When an action was taken, subsequent inappropriate shock was reduced (5.3% vs 49.2% at 1 year; P = .002).ConclusionsPediatric and CHD patients are experiencing reduced inappropriate shocks with new generation ICD systems, though reduced lead fracture may account for this improvement. Clinical interventions after inappropriate shock favorably impact the subsequent rate of shocks once an inappropriate shock occurs.
dc.publisherWiley Periodicals, Inc.
dc.subject.othercongenital heart disease
dc.subject.otherICD
dc.subject.otherinappropriate shock
dc.subject.otherlead fracture
dc.subject.otherpediatric
dc.subject.othercomplication
dc.titleDecreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelInternal Medicine and Specialties
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/144309/1/chd12585_am.pdf
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/144309/2/chd12585.pdf
dc.identifier.doi10.1111/chd.12585
dc.identifier.sourceCongenital Heart Disease
dc.identifier.citedreferenceFarwell D, Green MS, Lemery R, Gollob MH, Birnie DH. Accelerating risk of Fidelis lead fracture. Hear Rhythm. 2008; 5 ( 10 ): 1375 – 1379.
dc.identifier.citedreferenceDeWitt ES, Triedman JK, Cecchin F, et al. Time dependence of risks and benefits in pediatric primary prevention implantable cardioverter‐defibrillator therapy. Circ Arrhythmia Electrophysiol. 2014; 7 ( 6 ): 1057 – 1063.
dc.identifier.citedreferenceKorte T, Köditz H, Niehaus M, Paul T, Tebbenjohanns J. High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. Pacing Clin Electrophysiol PACE. 2004; 27 ( 7 ): 924 – 932.
dc.identifier.citedreferenceKolb C, Sturmer M, Sick P, et al. Reduced risk for inappropriate implantable cardioverter‐defibrillator shocks with dual‐chamber therapy compared with single‐chamber therapy: results of the randomized OPTION study. JACC Hear Fail. 2014; 2 ( 6 ): 611 – 619.
dc.identifier.citedreferenceHendrik S, Thomas B, Johannes K, et al. Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death : DECREASE study. Clin Res Cardiol. 2015; 104 ( 12 ): 1021 – 1032.
dc.identifier.citedreferenceWathen MS, DeGroot PJ, Sweeney MO, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter‐defibrillators: pacing fast ventricular tachycardia reduces shock therapies. Circulation. 2004; 110 ( 17 ): 2591 – 2596.
dc.identifier.citedreferenceWilkoff BL, Williamson BD, Stern RS, et al. Strategic programming of detection and therapy parameters in implantable cardioverter‐defibrillators reduces shocks in primary prevention patients. Results from the PREPARE (Primary Prevention Parameters Evaluation) study. J Am Coll Cardiol. 2008; 52 ( 7 ): 541 – 550.
dc.identifier.citedreferenceMoss AJ, Schuger C, Beck C. A, et al. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med. 2012; 367 ( 24 ): 2275 – 2283.
dc.identifier.citedreferenceDaubert JP, Zareba W, Cannom DS, et al. Inappropriate implantable cardioverter‐defibrillator shocks in MADIT II. Frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008; 51 ( 14 ): 1357 – 1365.
dc.identifier.citedreferenceMastenbroek MH, Pedersen SS, Van Der Tweel I, Doevendans PA, Meine M. Results of ENHANCED implantable cardioverter defibrillator programming to reduce therapies and improve quality of life (from the ENHANCED‐ICD study). Am J Cardiol. 2016; 117 ( 4 ): 596 – 604.
dc.identifier.citedreferenceBiton Y, Huang DT, Goldenberg I, et al. Relationship between age and inappropriate implantable cardioverter‐defibrillator therapy in MADIT‐RIT (Multicenter Automatic Defibrillator Implantation Trial‐Reduce Inappropriate Therapy). Hear Rhythm. 2016; 13 ( 4 ): 888 – 893.
dc.identifier.citedreferenceWebster G, Panek KA, Labella M, et al. Psychiatric functioning and quality of life in young patients with cardiac rhythm devices. Pediatrics. 2014; 133 ( 4 ): e964 – e972.
dc.identifier.citedreferenceCosta R, Silva KR, da Mendonça RC, et al. Incidence of shock and quality of life in young patients with implantable cardioverter‐defibrillator. Arq Bras Cardiol. 2007; 88 ( 3 ): 258 – 264.
dc.identifier.citedreferenceMessali A, Thomas O, Chauvin M, Coumel P, Leenhardt A. Death due to an implantable cardioverter defibrillator. J Cardiovasc Electrophysiol. 2004; 15 ( 8 ): 953 – 956.
dc.identifier.citedreferenceAtallah J, Erickson CC, Cecchin F, et al. Multi‐institutional study of implantable defibrillator lead performance in children and young adults results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study. Circulation. 2013; 127 ( 24 ): 2393 – 2402.
dc.identifier.citedreferenceVan Rees JB, Van Welsenes GH, Borleffs CJW, et al. Update on small‐diameter implantable cardioverter‐defibrillator leads performance. PACE ‐ Pacing Clin Electrophysiol. 2012; 35 ( 6 ): 652 – 658.
dc.identifier.citedreferenceBeukema RJ, Misier AR, Delnoy PP, Smit JJ, Elvan A. Characteristics of Sprint Fidelis lead failure. Neth Hear J. 2010; 18 ( 1 ): 12 – 17.
dc.identifier.citedreferenceHauser RG, Maisel WH, Friedman PA, et al. Longevity of sprint fidelis implantable cardioverter‐defibrillator leads and risk factors for failure: implications for patient management. Circulation. 2011; 123 ( 4 ): 358 – 363.
dc.identifier.citedreferenceAuricchio A, Schloss EJ, Kurita T, et al. Low inappropriate shock rates in patients with single‐ and dual/triple‐chamber implantable cardioverter‐defibrillators using a novel suite of detection algorithms: painFree SST trial primary results. Hear Rhythm. 2015; 12 ( 5 ): 926 – 936.
dc.identifier.citedreferenceKeren A, Sears SF, Nery P, et al. Psychological adjustment in ICD patients living with advisory fidelis leads. J Cardiovasc Electrophysiol. 2011; 22 ( 1 ): 57 – 63.
dc.identifier.citedreferenceEicken A, Kolb C, Lange S, et al. Implantable cardioverter defibrillator (ICD) in children. Int J Cardiol. 2006; 107 ( 1 ): 30 – 35.
dc.identifier.citedreferenceGarnreiter JM, Pilcher TA, Etheridge SP, Saarel EV. Inappropriate ICD shocks in pediatrics and congenital heart disease patients: risk factors and programming strategies. Hear Rhythm. 2015; 12 ( 5 ): 937 – 942.
dc.identifier.citedreferenceVon Bergen NH, Atkins DL, Dick M, et al. Multicenter study of the effectiveness of implantable cardioverter defibrillators in children and young adults with heart disease. Pediatr Cardiol. 2011; 32 ( 4 ): 399 – 405.
dc.identifier.citedreferenceTen Harkel ADJ, Blom NA, Reimer AG, Tukkie R, Sreeram N, Bink‐Boelkens MTE. Implantable cardioverter defibrillator implantation in children in The Netherlands. Eur J Pediatr. 2005; 164 ( 7 ): 436 – 441.
dc.identifier.citedreferenceMezu U, Ch I, Halder I, London B, Saba S. Women and minorities are less likely to receive an implantable cardioverter defibrillator for primary prevention of sudden cardiac death. Europace. 2012; 14 ( 3 ): 341 – 344.
dc.identifier.citedreferenceRusso AM, Hafley GE, Lee KL, et al. Racial differences in outcome in the Multicenter UnSustained Tachycardia Trial (MUSTT): a comparison of whites versus blacks. Circulation. 2003; 108 ( 1 ): 67 – 72.
dc.identifier.citedreferenceGasparini M, Proclemer A, Klersy C, et al. Effect of long‐detection interval vs standard‐detection interval for implantable cardioverter‐defibrillators on antitachycardia pacing and shock delivery. JAMA. 2013; 309 ( 18 ): 1903.
dc.identifier.citedreferenceKalra Y, Radbill AE, Johns JA, Fish FA, Kannankeril PJ. Antitachycardia pacing reduces appropriate and inappropriate shocks in children and congenital heart disease patients. Hear Rhythm. 2012; 9 ( 11 ): 1829 – 1834.
dc.identifier.citedreferenceLawrence D, Von Bergen N, Law IH, et al. Inappropriate ICD discharges in single‐chamber versus dual‐chamber devices in the pediatric and young adult population. J Cardiovasc Electrophysiol. 2009; 20 ( 3 ): 287 – 290.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.