dc.description.abstractMRI provides comprehensive information on the full range of kidney diseases, including benign and malignant processes and diffuse renal parenchymal disease. This unit presents a set protocols incorporating various types of sequences including transverse, coronal and sagittal data acquisition, and the routine use of intravenous gadolinium.
dc.publisherLippincott‐Raven
dc.publisherWiley Periodicals, Inc.
dc.titleMRI of the Kidney
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelRadiology
dc.subject.hlbsecondlevelFamily Medicine and Primary Care
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/145420/1/cpmia1601.pdf
dc.identifier.doi10.1002/0471142719.mia1601s00
dc.identifier.sourceCurrent Protocols in Magnetic Resonance Imaging
dc.identifier.citedreferenceBalci, N.C., Semelka, R.C., Patt, R.H., Dubois, D., Freeman, J.A., Gomez‐Caminero, A., and Woosley, J.T. 1999. Complex renal cysts: Findings on MR images. Am. J. Roentgenol. 172: 1495 ‐ 1500.
dc.identifier.citedreferenceHricak, H., Thoeni, R.F., Carroll, P.R., Demas, B.E., Marotti, M., and Tanagho, E.A. 1988. Detection and staging of renal neoplasms: A reassessment of MR imaging. Radiology. 166: 643 ‐ 649.
dc.identifier.citedreferenceHuch Boni, R.A., Debatin, J.F., and Krestin, G.P. 1996. Contrast‐enhanced MR imaging of the kidneys and adrenal glands. Magn. Reson. Imaging Clinics of North America. 4(1): 101 ‐ 131.
dc.identifier.citedreferenceJohn, G., Semelka, R.C., Burdeny, D.A., Kelekis, N.L., Woosley, J.T., Kettritz, U., and Freeman, J.A. 1997. Renal cell cancer: Incidence of hemorrhage on MR images in patients with chronic renal insufficiency. J. Magn. Reson. Imaging. 7: 157 ‐ 60.
dc.identifier.citedreferenceRofsky, N.M., Weinreb, J.C., Bosniak, M.A., Libes, R.B., and Birnbaum, B.A. 1991. Renal lesion characterization with Gadolinium‐enhanced MR imaging: Efficacy and safety in patients with renal insufficiency. Radiology. 180: 85 ‐ 89.
dc.identifier.citedreferenceSemelka, R.C., Hricak, H., Stevens, S.K., Fingold, R., Tomei, E., and Carroll, P.R. 1991. Combined gadolinium‐enhanced and fat saturation MR imaging of renal masses. Radiology. 178: 803 ‐ 809.
dc.identifier.citedreferenceSemelka, R.C., Shoenut, J.P., Kroeker, M.A., MacMahon, R.G., and Greenberg, H.M. 1992. Renal lesions: controlled comparison between CT and 1.5T MR imaging with nonenhanced and gadolinium‐enhanced fat‐suppressed spin‐echo and breath‐hold FLASH techniques. Radiology. 182: 425 ‐ 430.
dc.identifier.citedreferenceSemelka, R.C., Shoenut, J.P., Magro, C.M., Kroeker, M.A., MacMahon, R., and Greenberg, H.M. 1993. Renal cancer staging: Comparison of contrast‐enhanced CT and gadolinium‐enhanced fat‐suppressed spin‐echo and gradient‐echo MR imaging. J. Magn. Reson. Imaging. 3: 597 ‐ 602.
dc.identifier.citedreferenceShellock, F.G. 1996. Pocket Guide to MR Procedures and Metallic Objects. Lippincott‐Raven, Philadelphia.
dc.identifier.citedreferenceShellock, F.G. 1996.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.