Reasons for cessation of clean intermittent catheterization after spinal cord injury: Results from the Neurogenic Bladder Research Group spinal cord injury registry
dc.contributor.author | Patel, Darshan P. | |
dc.contributor.author | Herrick, Jennifer S. | |
dc.contributor.author | Stoffel, John T. | |
dc.contributor.author | Elliott, Sean P. | |
dc.contributor.author | Lenherr, Sara M. | |
dc.contributor.author | Presson, Angela P. | |
dc.contributor.author | Welk, Blayne | |
dc.contributor.author | Jha, Amitabh | |
dc.contributor.author | Myers, Jeremy B. | |
dc.date.accessioned | 2020-02-05T15:07:01Z | |
dc.date.available | WITHHELD_12_MONTHS | |
dc.date.available | 2020-02-05T15:07:01Z | |
dc.date.issued | 2020-01 | |
dc.identifier.citation | Patel, Darshan P.; Herrick, Jennifer S.; Stoffel, John T.; Elliott, Sean P.; Lenherr, Sara M.; Presson, Angela P.; Welk, Blayne; Jha, Amitabh; Myers, Jeremy B. (2020). "Reasons for cessation of clean intermittent catheterization after spinal cord injury: Results from the Neurogenic Bladder Research Group spinal cord injury registry." Neurourology and Urodynamics 39(1): 211-219. | |
dc.identifier.issn | 0733-2467 | |
dc.identifier.issn | 1520-6777 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/153674 | |
dc.description.abstract | IntroductionClean intermittent catheterization (CIC) is recommended for bladder management after spinal cord injury (SCI) since it has the lowest complication rate. However, transitions from CIC to other less optimal strategies, such as indwelling catheters (IDCs) are common. In individuals with SCI who stopped CIC, we sought to determine how individual characteristics affect the bladder‐related quality of life (QoL) and the reasons for CIC cessation.MethodsThe Neurogenic Bladder Research Group registry is an observational study, evaluating neurogenic bladder‐related QoL after SCI. From 1479 participants, those using IDC or urinary conduit were asked if they had ever performed CIC, for how long, and why they stopped CIC. Multivariable regression, among participants discontinuing CIC, established associations between demographics, injury characteristics, and SCI complications with bladder‐related QoL.ResultsThere were 176 participants who had discontinued CIC; 66 (38%) were paraplegic and 110 (63%) were male. The most common reasons for CIC cessation among all participants were inconvenience, urinary leakage, and too many urine infections. Paraplegic participants who discontinued CIC had higher mean age, better fine motor scores, and lower educational attainment and employment. Multivariable regression revealed years since SCI was associated with worse bladder symptoms (neurogenic bladder symptom score), ≥4 urinary tract infections (UTIs) in a year was associated with worse satisfaction and feelings about bladder symptoms (SCI‐QoL difficulties), while tetraplegia was associated better satisfaction and feelings about bladder symptoms (SCI‐QoL difficulties).ConclusionsTetraplegics who have discontinued CIC have an improved QoL compared with paraplegics. SCI individuals who have discontinued CIC and have recurrent UTIs have worse QoL. | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.subject.other | catheters | |
dc.subject.other | indwelling | |
dc.subject.other | intermittent urethral catheterization | |
dc.subject.other | patient‐reported outcome measures | |
dc.subject.other | quality of life | |
dc.subject.other | spinal cord injuries | |
dc.subject.other | urinary bladder | |
dc.title | Reasons for cessation of clean intermittent catheterization after spinal cord injury: Results from the Neurogenic Bladder Research Group spinal cord injury registry | |
dc.type | Article | |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.description.bitstreamurl | https://deepblue.lib.umich.edu/bitstream/2027.42/153674/1/nau24172_am.pdf | |
dc.description.bitstreamurl | https://deepblue.lib.umich.edu/bitstream/2027.42/153674/2/nau24172.pdf | |
dc.identifier.doi | 10.1002/nau.24172 | |
dc.identifier.source | Neurourology and Urodynamics | |
dc.identifier.citedreference | Patel DP, Lenherr SM, Stoffel JT, et al. Study protocol: patient reported outcomes for bladder management strategies in spinal cord injury. BMC Urol. 2017; 17 ( 1 ): 95. | |
dc.identifier.citedreference | Weld KJ, Dmochowski RR. Effect of bladder management on urological complications in spinal cord injured patients. J Urol. 2000; 163 ( 3 ): 768 ‐ 772. | |
dc.identifier.citedreference | Bennett CJ, Young MN, Adkins RH, Diaz F. Comparison of bladder management complication outcomes in female spinal cord injury patients. J Urol. 1995; 153 ( 5 ): 1458 ‐ 1460. | |
dc.identifier.citedreference | Groah SL, Weitzenkamp DA, Lammertse DP, Whiteneck GG, Lezotte DC, Hamman RF. Excess risk of bladder cancer in spinal cord injury: evidence for an association between indwelling catheter use and bladder cancer. Arch Phys Med Rehabil. 2002; 83 ( 3 ): 346 ‐ 351. | |
dc.identifier.citedreference | Chen Y, DeVivo M, Roseman J. Current trend and risk factors for kidney stones in persons with spinal cord injury: a longitudinal study. Spinal Cord. 2000; 38 ( 6 ): 346 ‐ 353. | |
dc.identifier.citedreference | Jaggi A, Drake M, Siddiqui E, Fatoye F. A comparison of the treatment recommendations for neurogenic lower urinary tract dysfunction in the national institute for health and care excellence, European Association of Urology and international consultations on incontinence guidelines. Neurourol Urodyn. 2018; 37: 2273 ‐ 2280. | |
dc.identifier.citedreference | Drake MJ, Apostolidis A, Cocci A, et al. Neurogenic lower urinary tract dysfunction: clinical management recommendations of the Neurologic Incontinence committee of the Fifth International Consultation on Incontinence 2013. Neurourol Urodyn. 2016; 35 ( 6 ): 657 ‐ 665. | |
dc.identifier.citedreference | Groen J, Pannek J, Castro Diaz D, et al. Summary of European Association of Urology (EAU) Guidelines on Neuro‐Urology. Eur Urol. 2016; 69 ( 2 ): 324 ‐ 333. | |
dc.identifier.citedreference | Cameron AP, Wallner LP, Tate DG, Sarma AV, Rodriguez GM, Clemens JQ. Bladder management after spinal cord injury in the United States 1972 to 2005. J Urol. 2010; 184 ( 1 ): 213 ‐ 217. | |
dc.identifier.citedreference | Yavuzer G, Gök H, Tuncer S, Soygür T, Arikan N, Arasil T. Compliance with bladder management in spinal cord injury patients. Spinal Cord. 2000; 38 ( 12 ): 762 ‐ 765. | |
dc.identifier.citedreference | Zlatev DV, Shem K, Elliott CS. Predictors of long‐term bladder management in spinal cord injury patients—upper extremity function may matter most. Neurourol Urodyn. 2018; 37 ( 3 ): 1106 ‐ 1112. | |
dc.identifier.citedreference | Afsar SI, Yemisci OU, Cosar SNS, Cetin N. Compliance with clean intermittent catheterization in spinal cord injury patients: a long‐term follow‐up study. Spinal Cord. 2013; 51 ( 8 ): 645 ‐ 649. | |
dc.identifier.citedreference | Lane GI, Driscoll A, Tawfik K, Chrouser K. A cross‐sectional study of the catheter management of neurogenic bladder after traumatic spinal cord injury. Neurourol Urodyn. 2018; 37 ( 1 ): 360 ‐ 367. | |
dc.identifier.citedreference | Vaidyanathan S, Soni BM, Singh G, Oo T, Hughes PL. Barriers to implementing intermittent catheterisation in spinal cord injury patients in Northwest Regional Spinal Injuries Centre, Southport, U.K. ScientificWorldJournal. 2011; 11: 77 ‐ 85. | |
dc.identifier.citedreference | Crescenze IM, Myers JB, Lenherr SM, et al. Predictors of low urinary quality of life in spinal cord injury patients on clean intermittent catheterization. Neurourol. Urodyn. 2019; 38: 1332 ‐ 1338. | |
dc.identifier.citedreference | Charlson ME, Pompei P, Ales KL, MacKenzie CR. A new method of classifying prognostic comorbidity in longitudinal studies: development and validation. J Chronic Dis. 1987; 40 ( 5 ): 373 ‐ 383. | |
dc.identifier.citedreference | Krogh K, Christensen P, Sabroe S, Laurberg S. Neurogenic bowel dysfunction score. Spinal Cord. 2006; 44 ( 10 ): 625 ‐ 631. | |
dc.identifier.citedreference | Tulsky DS, Kisala PA, Tate DG, Spungen AM, Kirshblum SC. Development and psychometric characteristics of the SCI‐QOL bladder management difficulties and bowel management difficulties item banks and short forms and the SCI‐QOL bladder complications scale. J Spinal Cord Med. 2015; 38 ( 3 ): 288 ‐ 302. | |
dc.identifier.citedreference | Tulsky DS, Kisala PA, Victorson D, et al. Overview of the spinal cord injury—quality of life (SCI‐QOL) measurement system. J Spinal Cord Med. 2015; 38 ( 3 ): 257 ‐ 269. | |
dc.identifier.citedreference | Welk B, Morrow S, Madarasz W, Baverstock R, Macnab J, Sequeira K. The validity and reliability of the neurogenic bladder symptom score. J Urol. 2014; 192 ( 2 ): 452 ‐ 457. | |
dc.identifier.citedreference | Hagen EM, Rekand T. Management of bladder dysfunction and satisfaction of life after spinal cord injury in Norway. J Spinal Cord Med. 2014; 37 ( 3 ): 310 ‐ 316. | |
dc.identifier.citedreference | Roth JD, Pariser JJ, Stoffel JT, et al. Patient subjective assessment of urinary tract infection frequency and severity is associated with bladder management method in spinal cord injury. Spinal Cord. 2019; 57: 700 ‐ 707. | |
dc.identifier.citedreference | Myers JB, Lenherr SM, Stoffel JT, et al. Patient reported bladder related symptoms and quality of life after spinal cord injury with different bladder management strategies. J Urol. 2019; 202: 574 ‐ 584. https://doi.org/101097ju0000000000000270 | |
dc.identifier.citedreference | Patel DP, Elliott SP, Stoffel JT, Brant WO, Hotaling JM, Myers JB. Patient reported outcomes measures in neurogenic bladder and bowel: a systematic review of the current literature. Neurourol Urodyn. 2016; 35 ( 1 ): 8 ‐ 14. | |
dc.identifier.citedreference | Myers JB, Lenherr SM, Stoffel JT, et al. The effects of augmentation cystoplasty and botulinum toxin injection on patient‐reported bladder function and quality of life among individuals with spinal cord injury performing clean intermittent catheterization. Neurourol Urodyn. 2019; 38 ( 1 ): 285 ‐ 294. | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.