Show simple item record

Operating- point insensitive voltage control of the Z- source inverter based on an indirect capacitor current control

dc.contributor.authorLee, Kwang‐woon
dc.contributor.authorKim, Taehyung
dc.date.accessioned2021-01-05T18:46:02Z
dc.date.available2021-01-05T18:46:02Z
dc.date.issued2015-08
dc.identifier.citationLee, Kwang‐woon ; Kim, Taehyung (2015). "Operating- point insensitive voltage control of the Z- source inverter based on an indirect capacitor current control." IET Power Electronics 8(8): 1358-1366.
dc.identifier.issn1755-4535
dc.identifier.issn1755-4543
dc.identifier.urihttps://hdl.handle.net/2027.42/163851
dc.publisherThe Institution of Engineering and Technology
dc.publisherWiley Periodicals, Inc.
dc.subject.otherinvertors
dc.subject.other(B2130) Capacitors
dc.subject.other(B1210) Power electronics, supply and supervisory circuits
dc.subject.other(C3110D) Current control
dc.subject.other(C3340H) Control of electric power systems
dc.subject.other(C3110B) Voltage control
dc.subject.othertransient response
dc.subject.othercurrent control dynamics
dc.subject.otherZ- network inductor current control
dc.subject.otherZ- network capacitor voltage
dc.subject.othersmall- signal model- based controls
dc.subject.otherZSI
dc.subject.othercapacitor voltage control
dc.subject.otherindirect capacitor current control
dc.subject.otherZ- source inverter
dc.subject.otheroperating- point insensitive voltage control
dc.subject.othercapacitors
dc.subject.otherelectric current control
dc.subject.othervoltage control
dc.titleOperating- point insensitive voltage control of the Z- source inverter based on an indirect capacitor current control
dc.typeArticle
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelElectrical Engineering
dc.subject.hlbtoplevelEngineering
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/163851/1/pel2bf02952.pdf
dc.identifier.doi10.1049/iet-pel.2014.0463
dc.identifier.sourceIET Power Electronics
dc.identifier.citedreferencePeng F.Z., Joseph A., and Wang J. et al.: - Z- source inverter for motor drives - , IEEE Trans. Power Electron., 2005, 20, ( 4 ), pp. 857 - 863 (doi: http://doi.org/10.1109/TPEL.2005.850938 )
dc.identifier.citedreferencePeng F.Z.: - Z- source inverter - , IEEE Trans. Ind. Appl., 2003, 39, ( 2 ), pp. 504 - 510 (doi: http://doi.org/10.1109/TIA.2003.808920 )
dc.identifier.citedreferenceOgata K.: - Modern control engineering - ( Prentice Hall, 2010 )
dc.identifier.citedreferenceSul S.K.: - Control of electric machine drive systems - ( John Wiley & Sons, 2011 )
dc.identifier.citedreferenceHa J.I.: - Voltage injection method for three- phase current reconstruction in PWM inverters using a single sensor - , IEEE Trans. Power Electron., 2009, 24, ( 3 ), pp. 767 - 775 (doi: http://doi.org/10.1109/TPEL.2008.2009451 )
dc.identifier.citedreferenceLee D.C., and Lim D.S.: - AC voltage and current sensorless control of three- phase PWM rectifiers - , IEEE Trans. Power Electron., 2002, 17, ( 6 ), pp. 883 - 890 (doi: http://doi.org/10.1109/TPEL.2002.805592 )
dc.identifier.citedreferenceLoh P.C., Vilathgamuwa D.M., Lai Y.S., Chua G.T., and Li Y.: - Pulsewidth modulation of Z- source inverters - , IEEE Trans. Power Electron., 2005, 20, ( 6 ), pp. 1346 - 1355 (doi: http://doi.org/10.1109/TPEL.2005.857543 )
dc.identifier.citedreferenceTran Q.V., Chun T.W., Ahn J.R., and Lee H.H.: - Algorithms for controlling both the DC boost and ac output voltage of Z- source inverter - , IEEE Trans. Ind. Electron., 2007, 54, ( 5 ), pp. 2745 - 2750 (doi: http://doi.org/10.1109/TIE.2007.895146 )
dc.identifier.citedreferenceLiu Y., Ge B., and Abu- Rub H.: - Theoretical and experimental evaluation of four space vector modulations applied to quasi- Z- source inverters - , IET Power Electron., 2013, 6, ( 7 ), pp. 1257 - 1269 (doi: http://doi.org/10.1049/iet- pel.2012.0681 )
dc.identifier.citedreferencePeng F.Z., Shen M., and Qian Z.: - Maximum boost control of the Z- source inverter - , IEEE Trans. Power Electron., 2005, 20, ( 4 ), pp. 833 - 838 (doi: http://doi.org/10.1109/TPEL.2005.850927 )
dc.identifier.citedreferenceShen M., Wang J., and Joseph A. et al.: - Constant boost control of the Z- source inverter to minimize current ripple and voltage stress - , IEEE Trans. Ind. Appl., 2006, 42, ( 3 ), pp. 770 - 778 (doi: http://doi.org/10.1109/TIA.2006.872927 )
dc.identifier.citedreferenceLiu H., Liu P., and Zhang Y.: - Design and digital implementation of voltage and current mode control for the quasi- Z- source converters - , IET Power Electron., 2013, 6, ( 6 ), pp. 990 - 998 (doi: http://doi.org/10.1049/iet- pel.2012.0366 )
dc.identifier.citedreferenceEllabban O., VanMierlo J., and Lataire P.: - A DSP- based dual- loop peak dc- link voltage control strategy of the Z- source inverter - , IEEE Trans. Power Electron., 2012, 29, ( 9 ), pp. 4088 - 4097 (doi: http://doi.org/10.1109/TPEL.2012.2189588 )
dc.identifier.citedreferenceGaligekere V.P., and Kazimierczuk M.K.: - Small- signal modeling of PWM Z- source converter by circuit- averaging technique - , IEEE Int. Symp. Circuits Syst., 2011, pp. 1600 - 1603
dc.identifier.citedreferenceLiu J., Hu J., and Xu L.: - Dynamic modeling and analysis of Z source converter- derivation of AC small signal model and design- oriented analysis - , IEEE Trans. Power Electron., 2007, 22, ( 5 ), pp. 1786 - 1796 (doi: http://doi.org/10.1109/TPEL.2007.904219 )
dc.identifier.citedreferenceLoh P.C., Vilathgamuwa D.M., Gajanayake C.J., Lim Y.R., and Teo C.W.: - Transient modeling and analysis of pulse- width modulated Z source inverter - , IEEE Trans. Power Electron., 2007, 22, ( 2 ), pp. 498 - 507 (doi: http://doi.org/10.1109/TPEL.2006.889929 )
dc.identifier.citedreferenceRajakaruna S., and Jayawickrama L.: - Steady- state analysis and designing impedance network of Z- source inverters - , IEEE Trans. Ind. Electron., 2010, 57, ( 7 ), pp. 2483 - 2491 (doi: http://doi.org/10.1109/TIE.2010.2047990 )
dc.identifier.citedreferenceShen M., and Peng F.Z.: - Operation modes and characteristics of the Z source inverter with small inductance or low power factor - , IEEE Trans. Ind. Electron., 2008, 55, ( 1 ), pp. 89 - 96 (doi: http://doi.org/10.1109/TIE.2007.909063 )
dc.identifier.citedreferenceShen M., Joseph A., Wang J., Peng F.Z., and Adams D.J.: - Comparison of traditional inverters and Z- source inverter for fuel cell vehicles - , IEEE Trans. Power Electron., 2007, 22, ( 4 ), pp. 1453 - 1463 (doi: http://doi.org/10.1109/TPEL.2007.900505 )
dc.identifier.citedreferenceSiwakoti Y.P., Blaabjerg F., Loh P.C., and Town G.E.: - High- voltage boost quasi- Z- source isolated DC/DC converter - , IET Power Electron., 2014, 7, ( 9 ), pp. 2387 - 2395 (doi: http://doi.org/10.1049/iet- pel.2013.0845 )
dc.identifier.citedreferenceLiu Y., Ge B., Abu- Rub H., and Peng F.Z.: - Modelling and controller design of quasi- Z- source inverter with battery- based photovoltaic power system - , IET Power Electron., 2014, 7, ( 7 ), pp. 1665 - 1674 (doi: http://doi.org/10.1049/iet- pel.2013.0389 )
dc.identifier.citedreferenceHanif M., Basu M., and Gaughan K.: - Understanding the operation of a Z- source inverter for photovoltaic application with a design example - , IET Power Electron., 2011, 4, ( 3 ), pp. 278 - 287 (doi: http://doi.org/10.1049/iet- pel.2009.0176 )
dc.identifier.citedreferenceHuang Y., Shen M., Peng F.Z., and Wang J.: - Z- source inverter for residential photovoltaic systems - , IEEE Trans. Power Electron., 2006, 21, ( 6 ), pp. 1776 - 1782 (doi: http://doi.org/10.1109/TPEL.2006.882913 )
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.