Validation of a Robust Method for Quantification of Three-Dimensional Growth of the Thoracic Aorta Using Deformable Image Registration
Bian, Zhangxing; Zhong, Jiayang; Dominic, Jeffrey; Christensen, Gary; Hatt, Charles; Burris, Nicholas
2021-03-02
View/ Open
Abstract
Purpose: Accurate assessment of thoracic aortic aneurysm (TAA) growth is important for appropriate clinical management. Maximal aortic diameter is the primary metric that is used to assess growth, but it suffers from substantial measurement variability. A recently proposed technique, termed Vascular Deformation Mapping (VDM), is able to quantify three-dimensional aortic growth using clinical computed tomography angiography (CTA) data using an approach based on deformable image registration (DIR). However, the accuracy and robustness of VDM remains undefined given the lack of a ground truth from clinical CTA data, and furthermore the performance of VDM relative to standard manual diameter measurements is unknown. Methods: To evaluate the performance of the VDM pipeline for quantifying aortic growth we developed a novel and systematic evaluation process to generate 31 unique synthetic CTA growth phantoms with variable degrees and locations of aortic wall deformation. Aortic deformation was quantified using two metrics: Area Ratio (AR), defined as the ratio of surface area in triangular mesh elements, and the magnitude of deformation in the normal direction (DiN) relative to the aortic surface. Using these phantoms, we further investigated the effects on VDM’s measurement accuracy resulting from factors that influence quality of clinical CTA data such as respiratory translations, slice thickness and image noise. Lastly, we compare the measurement error of VDM TAA growth assessments against two expert raters performing standard diameter measurements of synthetic phantom images. Results: Across our population of 31 synthetic growth phantoms, the median ab- solute error was 0.048 (IQR: 0.077-0.037) for AR and 0.138mm (IQR: 0.227-0.107mm) for DiN. Median relative error was 1.9% for AR and < 6.4% for DiN at the highest tested noise level (CNR = 2.66). Error in VDM output increased with slice thickness, with highest median relative error of 1.4% for AR and 6.3% for DiN at slice thickness of 2.0 mm. Respiratory motion of the aorta resulted in maximal absolute error of 3% AR and 0.6 mm in DiN, but bulk translations in aortic position had a very small effect on measured AR and DiN values (relative errors < 1%). VDM-derived measurements of magnitude and location of maximal diameter change demonstrated significantly high accuracy and lower variability compared to two expert manual raters (p < 0.03 across all comparisons). Conclusions: VDM yields accurate, three-dimensional assessment of aortic growth in TAA patients and is robust to factors such as image noise, respiration-induced translations and differences in patient position. Further, VDM significantly outperformed two expert manual raters in assessing the magnitude and location of aortic growth despite optimized experimental measurement conditions. These results support validation of the VDM technique for accurate quantification of aortic growth in patients and highlight important several advantages over current measurement techniques.Deep Blue DOI
Subjects
vascular deformation mapping aortic growth thoracic aortic aneurysm deformable registaration
Types
Working Paper
Metadata
Show full item recordCollections
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.