Rapid identification of pathogens associated with ventilator-associated pneumonia by Nanopore sequencing
dc.contributor.author | Wu, Nan | |
dc.contributor.author | Ranjan, Piyush | |
dc.contributor.author | Tao, Changyu | |
dc.contributor.author | Liu, Chao | |
dc.contributor.author | Yang, Ence | |
dc.contributor.author | He, Bei | |
dc.contributor.author | Erb-Downward, John R. | |
dc.contributor.author | Bo, Shining | |
dc.contributor.author | Zheng, Jiajia | |
dc.contributor.author | Guo, Chenxia | |
dc.contributor.author | Liu, Beibei | |
dc.contributor.author | Sun, Lina | |
dc.contributor.author | Yan, Wei | |
dc.contributor.author | Wang, Meng | |
dc.contributor.author | Wang, Wenting | |
dc.contributor.author | Wen, Jianing | |
dc.contributor.author | Yang, Ping | |
dc.contributor.author | Yang, Lin | |
dc.contributor.author | Tian, Qiaoshan | |
dc.contributor.author | Dickson, Robert P. | |
dc.contributor.author | Shen, Ning | |
dc.date.accessioned | 2022-08-10T18:25:12Z | |
dc.date.available | 2022-08-10T18:25:12Z | |
dc.date.issued | 2021-12-10 | |
dc.identifier.citation | Respiratory Research. 2021 Dec 10;22(1):310 | |
dc.identifier.uri | https://doi.org/10.1186/s12931-021-01909-3 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/173727 | en |
dc.description.abstract | Abstract Background Aetiology detection is crucial in the diagnosis and treatment of ventilator-associated pneumonia (VAP). However, the detection method needs improvement. In this study, we used Nanopore sequencing to build a quick detection protocol and compared the efficiency of different methods for detecting 7 VAP pathogens. Methods The endotracheal aspirate (ETA) of 83 patients with suspected VAP from Peking University Third Hospital (PUTH) was collected, saponins were used to deplete host genomes, and PCR- or non-PCR-amplified library construction methods were used and compared. Sequence was performed with MinION equipment and local data analysis methods were used for sequencing and data analysis. Results Saponin depletion effectively removed 11 of 12 human genomes, while most pathogenic bacterial genome results showed no significant difference except for S. pneumoniae. Moreover, the average sequence time decreased from 19.6 h to 3.62 h. The non-PCR amplification method and PCR amplification method for library build has a similar average sensitivity (85.8% vs. 86.35%), but the non-PCR amplification method has a better average specificity (100% VS 91.15%), and required less time. The whole method takes 5–6 h from ETA extraction to pathogen classification. After analysing the 7 pathogens enrolled in our study, the average sensitivity of metagenomic sequencing was approximately 2.4 times higher than that of clinical culture (89.15% vs. 37.77%), and the average specificity was 98.8%. Conclusions Using saponins to remove the human genome and a non-PCR amplification method to build libraries can be used for the identification of pathogens in the ETA of VAP patients within 6 h by MinION, which provides a new approach for the rapid identification of pathogens in clinical departments. | |
dc.title | Rapid identification of pathogens associated with ventilator-associated pneumonia by Nanopore sequencing | |
dc.type | Journal Article | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/173727/1/12931_2021_Article_1909.pdf | |
dc.identifier.doi | https://dx.doi.org/10.7302/5458 | |
dc.language.rfc3066 | en | |
dc.rights.holder | The Author(s) | |
dc.date.updated | 2022-08-10T18:25:11Z | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.