Show simple item record

Infection prevention practices in the Netherlands: results from a National Survey

dc.contributor.authorHuis, Anita
dc.contributor.authorSchouten, Jeroen
dc.contributor.authorLescure, Dominique
dc.contributor.authorKrein, Sarah
dc.contributor.authorRatz, David
dc.contributor.authorSaint, Sanjay
dc.contributor.authorHulscher, Marlies
dc.contributor.authorGreene, M. T.
dc.date.accessioned2022-08-10T18:44:33Z
dc.date.available2022-08-10T18:44:33Z
dc.date.issued2020-01-06
dc.identifier.citationAntimicrobial Resistance & Infection Control. 2020 Jan 06;9(1):7
dc.identifier.urihttps://doi.org/10.1186/s13756-019-0667-3
dc.identifier.urihttps://hdl.handle.net/2027.42/173948en
dc.description.abstractAbstract Objective To examine the extent to which acute care hospitals in the Netherlands have adopted recommended practices to prevent catheter-associated urinary tract infection (CAUTI), central line-associated bloodstream infection (CLABSI), ventilator-associated pneumonia (VAP), and Clostridioides difficile infection (CDI). Methods Between 18 July 2017 and 31 October 2017, we surveyed the infection prevention teams of all acute care hospitals in the Netherlands. The survey instrument was based on the ‘Translating Healthcare-Associated Infection Prevention Research into Practice’ (TRIP) questionnaire and adapted to the Dutch context. Descriptive statistics were used to examine the reported regular use of CAUTI, CLABSI, VAP, and CDI prevention practices as well as the hospital characteristics. Results Out of 72 eligible hospitals, 47 (65.3%) responded. Surveillance systems for monitoring CAUTI, CLABSI, VAP, and CDI were present in 17.8, 95.4, 26.2, and 77.3% of hospitals, respectively. Antimicrobial stewardship programs have been established in 91.5% of participating hospitals. For CAUTI, the majority of hospitals regularly used aseptic technique during catheter insertion (95%) and portable bladder ultrasound scanners (86.1%). Intermittent catheterization and catheter stop-orders were regularly used by 65.8 and 62.2% of hospitals. For CLABSI, all hospitals regularly used maximum sterile barrier precautions and chlorhexidine gluconate for insertion site antisepsis. Avoidance of the femoral site for central line insertions was regularly used by 65.9% of hospitals. Urinary catheters and central-lines impregnated with antibiotics or antiseptics were rarely used (≤ 5%). Selective decontamination strategies for preventing VAP were used in 84% of hospitals. With the exception of disposable thermometers (31.8%), all prevention practices to prevent CDI were regularly used by more than 80% of hospitals. Conclusions Most Dutch hospitals report regular use of recommended practices for preventing CLABSI and CDI. Several specific practices to prevent CAUTI and VAP were less frequently used, however, providing an opportunity for improvement.
dc.titleInfection prevention practices in the Netherlands: results from a National Survey
dc.typeJournal Article
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/173948/1/13756_2019_Article_667.pdf
dc.identifier.doihttps://dx.doi.org/10.7302/5679
dc.language.rfc3066en
dc.rights.holderThe Author(s).
dc.date.updated2022-08-10T18:44:33Z
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.