Monte Carlo calculations of a bismuth germanate scintillation detector
dc.contributor.author | Alkhafaji, Salih M. | en_US |
dc.date.accessioned | 2006-04-07T18:02:49Z | |
dc.date.available | 2006-04-07T18:02:49Z | |
dc.date.issued | 1981-08-15 | en_US |
dc.identifier.citation | Alkhafaji, Salih M. (1981/08/15)."Monte Carlo calculations of a bismuth germanate scintillation detector." Nuclear Instruments and Methods 187(2-3): 547-551. <http://hdl.handle.net/2027.42/24280> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B73DN-470NXPG-4FP/2/fa1e7f7b2f86a543b38548df7f583f00 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/24280 | |
dc.description.abstract | Intrinsic efficiency, radial distribution of deposited energy and other properties of importance were investigated for bismuth germanate slabs via Monte Carlo calculation. The calculations were done for different slab thicknesses in the range 1/8"-2", and over the energy range 140-999 keV. An examination of the data shows the possible advantage of the use of BGO as scintillation detector for high energy gamma ray and positron imaging. The data do not show very strong dependence of the image resolution on the thickness of the slab. | en_US |
dc.format.extent | 240297 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | Monte Carlo calculations of a bismuth germanate scintillation detector | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Nuclear Engineering, The University of Michigan, Ann Arbor, Michigan 48109, U.S.A. | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/24280/1/0000546.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0029-554X(81)90387-6 | en_US |
dc.identifier.source | Nuclear Instruments and Methods | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.