Show simple item record

Automatic computer processing of digital 2-dimensional echocardiograms

dc.contributor.authorBuda, Andrew J.en_US
dc.contributor.authorDelp, Edward J.en_US
dc.contributor.authorMeyer, Charles R.en_US
dc.contributor.authorJenkins, Janice M.en_US
dc.contributor.authorSmith, David N.en_US
dc.contributor.authorBookstein, Fred L.en_US
dc.contributor.authorPitt, Bertramen_US
dc.date.accessioned2006-04-07T18:40:03Z
dc.date.available2006-04-07T18:40:03Z
dc.date.issued1983-08en_US
dc.identifier.citationBuda, Andrew J., Delp, Edward J., Meyer, Charles R., Jenkins, Janice M., Smith, David N., Bookstein, Fred L., Pitt, Bertram (1983/08)."Automatic computer processing of digital 2-dimensional echocardiograms." The American Journal of Cardiology 52(3): 384-389. <http://hdl.handle.net/2027.42/25152>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6T10-4BPB3NJ-1M3/2/8e6976634237648e49d7b9fa649fd583en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/25152
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=6869291&dopt=citationen_US
dc.description.abstractQuantitative studies of left ventricular function using 2-dimensional echocardiography have been limited because of a lack of computerized methods to automatically analyze the echocardiographic images. Previous computer efforts have been directed at digitizing the video output of the 2-D echocardiogram, but this digitizing method has significant limitations. A direct digitization method that produces improvement in signal-to-noise ratio and, subsequently, improved automatic detection of endocardial and epicardial borders, was developed. With definition of these edges, left ventricular global and regional analysis is possible frame by frame so that dynamic changes in cardiac function may be assessed throughout the cardiac cycle. Further technologic advances in 2-D echocardiographic acquisition and image processing should allow computer processing of 2-D echocardiographic data in real time.en_US
dc.format.extent817689 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleAutomatic computer processing of digital 2-dimensional echocardiogramsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelInternal Medicine and Specialtiesen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, Division of Radiologic Physics, Department of Radiology, and the Department of Electrical and Computer Engineering, University of Michigan, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationotherno department founden_US
dc.identifier.pmid6869291en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/25152/1/0000588.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0002-9149(83)90144-3en_US
dc.identifier.sourceThe American Journal of Cardiologyen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.