Show simple item record

Computer analysis of cardiac radionuclide data

dc.contributor.authorFroelich, Jerry W.en_US
dc.contributor.authorThrall, James H.en_US
dc.contributor.authorKalff, Victoren_US
dc.contributor.authorLeslie Rogers, W.en_US
dc.contributor.authorRabinovitch, Mark A.en_US
dc.date.accessioned2006-04-07T18:40:32Z
dc.date.available2006-04-07T18:40:32Z
dc.date.issued1983en_US
dc.identifier.citationFroelich, Jerry W., Thrall, James H., Kalff, Victor, Leslie Rogers, W., Rabinovitch, Mark (1983)."Computer analysis of cardiac radionuclide data." Progress in Cardiovascular Diseases 26(1): 43-74. <http://hdl.handle.net/2027.42/25165>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B75BG-4C4NW1T-C3/2/24049439e55565bc720f16455fa06395en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/25165
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=6346394&dopt=citationen_US
dc.description.abstractGamma-camera tomography gives uniform in-plane and cross-plane resolution with propagation of the defect from one plane to another determined only by the usual camera-collimator resolution. These images may be reformatted by computer to portray slices in any orientation. Cross plane resolution is slightly worse than for the other methods, but it is uniform. The efficiency is less than either quadrant slant hole or seven pinhole apertures. Rotating cameras are not portable nor can they be used for dynamic studies.Both slant hole collimators and seven pinhole apertures distort the object in the depth dimension because of the limited viewing angle. The slant hole geometry provides somewhat better sampling and less plane-to-plane cross talk especially for the more distant planes. The full width half maximum of the depth response is not a sensitive indicator of this problem because the depth response function has very long tails.To date, best overall performance of the limited angle methods is offered by the 40[deg] slant hole collimator on a large field-of-view camera. This, however, is not a portable unit and has a field-of-view too small for about 10% of the patients.Seven pinhole imaging offers the advantage of having been well studied by a number of institution.87-90 A large pool of normal patient studies exists and the performance is well documented. Although the seven pinhole alone is suited to dynamic studies, any of the methods may be adapted to multigated studies.en_US
dc.format.extent2867068 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleComputer analysis of cardiac radionuclide dataen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelInternal Medicine and Specialtiesen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Mich, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Mich, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Mich, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Mich, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Mich, USAen_US
dc.identifier.pmid6346394en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/25165/1/0000603.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0033-0620(83)90018-Xen_US
dc.identifier.sourceProgress in Cardiovascular Diseasesen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.