Show simple item record

Design of a real-time inspection system for NDE of reactor vessels and piping components

dc.contributor.authorGanapathy, S.en_US
dc.contributor.authorSchmult, B.en_US
dc.date.accessioned2006-04-07T19:10:57Z
dc.date.available2006-04-07T19:10:57Z
dc.date.issued1985en_US
dc.identifier.citationGanapathy, S., Schmult, B. (1985)."Design of a real-time inspection system for NDE of reactor vessels and piping components." International Journal of Pressure Vessels and Piping 20(1): 17-41. <http://hdl.handle.net/2027.42/25794>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6V3N-47Y9JDR-64/2/b5beb37104da7728cd85ac4fc9ba0661en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/25794
dc.description.abstractProgress in the development of a special-purpose system for use in a real-time in-service inspection system for reactor vessels and piping components is described in this report. An analysis of the synthetic aperture processing algorithm is presented and new methods of speedup are described. A number of special purpose processor architectures are presented and two of the more promising ones are described in detail and are compared and evaluated. Proposed specifications for an initial field inspection system are presented. A brief description of the capabilities of a laboratory prototype processor (to be fabricated) is given.en_US
dc.format.extent1039753 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleDesign of a real-time inspection system for NDE of reactor vessels and piping componentsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelMaterials Science and Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumUltrasonic Imaging Laboratory, Department of Electrical and Computer Engineering, The University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumUltrasonic Imaging Laboratory, Department of Electrical and Computer Engineering, The University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/25794/1/0000356.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0308-0161(85)90032-8en_US
dc.identifier.sourceInternational Journal of Pressure Vessels and Pipingen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.