Show simple item record

Determination of plasma trimetrexate levels using gas chromatography--mass spectrometry with selected-ion monitoring

dc.contributor.authorStetson, Phillip L.en_US
dc.contributor.authorEnsminger, William D.en_US
dc.date.accessioned2006-04-07T19:37:00Z
dc.date.available2006-04-07T19:37:00Z
dc.date.issued1986en_US
dc.identifier.citationStetson, P. L., Ensminger, W. D. (1986)."Determination of plasma trimetrexate levels using gas chromatography--mass spectrometry with selected-ion monitoring." Journal of Chromatography B: Biomedical Sciences and Applications 383(): 69-76. <http://hdl.handle.net/2027.42/26336>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6TG9-44BP4TY-90/2/abe1dbd670c643219d08df86929f3dc9en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/26336
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=2950125&dopt=citationen_US
dc.description.abstractTrimetrexate is a potent inhibitor of dihydrofolate reductase and has demonstrated significant antitumor activity against murine and human cell lines both in vitro and against several murine transplanted tumors. The importance of antifolate concentration and exposure time in determining toxic and therapeutic effects necessitates an assay of suitable sensitivity, accuracy and specifity for investigation of trimetrexate pharmacokinetics. This paper describes a gas chromatographic--mass spectrometric (GC--MS) procedure using selected-ion monitoring (SIM) for the determination of plasma trimetrexate levels. Using the C18 Bond-Elut extraction columns, the drug and internal standard are removed from plasma, derivatized to their bis(trimethylsilyl) derivatives and analysed by GC--SIM-MS. The reproducibility of the daily standard curves had coefficients of variation ranging from 4.9 to 11.4%. The precision of the assay yielded a coefficient of variation ranging from 5.6 to 10.1%, and the concentration means for the seeded control samples were found to be within -3.7 to +0.7% of the theoretical values for trimetrexate. No interfering peaks have been observed in application of the procedure on patient samples. The minimum detectable level under the conditions described was 0.005-0.014 [mu]M trimetrexate.en_US
dc.format.extent553125 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleDetermination of plasma trimetrexate levels using gas chromatography--mass spectrometry with selected-ion monitoringen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPublic Healthen_US
dc.subject.hlbsecondlevelChemistryen_US
dc.subject.hlbsecondlevelChemical Engineeringen_US
dc.subject.hlbsecondlevelBiological Chemistryen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.subject.hlbtoplevelScienceen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Pharmacology, Upjohn Center for Clinical Pharmacology, University of Michigan Medical School, Ann Arbor, MI 48109 U.S.A.en_US
dc.contributor.affiliationumDepartments of Pharmacology and Internal Medicine, Upjohn Center for Clinical Pharmacology, University of Michigan Medical School, Ann Arbor, MI 48109 U.S.A.en_US
dc.identifier.pmid2950125en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/26336/1/0000423.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/S0378-4347(00)83442-8en_US
dc.identifier.sourceJournal of Chromatography B: Biomedical Sciences and Applicationsen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.