The performance of an L3 hadron calorimeter prototype module with BGO
dc.contributor.author | Chen, C. | en_US |
dc.contributor.author | Chen, H. S. | en_US |
dc.contributor.author | Li, X. G. | en_US |
dc.contributor.author | Lu, Y. S. | en_US |
dc.contributor.author | Mao, Y. F. | en_US |
dc.contributor.author | Tang, X. W. | en_US |
dc.contributor.author | Tung, K. L. | en_US |
dc.contributor.author | Wang, C. N. | en_US |
dc.contributor.author | Yang, K. S. | en_US |
dc.contributor.author | Yang, Q. Y. | en_US |
dc.contributor.author | Zhuang, H. L. | en_US |
dc.contributor.author | Hofer, H. | en_US |
dc.date.accessioned | 2006-05-10T15:41:08Z | |
dc.date.available | 2006-05-10T15:41:08Z | |
dc.date.issued | 1988-11 | en_US |
dc.identifier.citation | Chen, C., Chen, H. S., Li, X. G., Lu, Y. S., Mao, Y. F., Tang, X. W., Tung, K. L., Wang, C. N., Yang, K. S., Yang, Q. Y., Zhuang, H. L., Hofer, H. (1988/11)."The performance of an L3 hadron calorimeter prototype module with BGO." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 272(3): 713-721. <http://hdl.handle.net/2027.42/27089> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B6TJM-473FJTT-91/2/1cca4ece0c48f584ff578176e88d10b8 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/27089 | |
dc.description.abstract | A prototype of a gas sampling uranium module of the L3 hadron calorimeter was built and subsequently tested with pion beams of energies between 4 and 20 GeV. The construction of the proportional chambers, the assembling of the module, the readout electronics, and the beam test are briefly described. The energy resolution of the calorimeter module alone was measured to be 30.5 +/- 3% at 6 GeV, 21 +/- 2% at 10 GeV and 18 +/- 2% at 20 GeV. For the module together with a BGO crystal matrix in resolution was 29 +/- 3% at 4 GeV, 21 +/- 2% at 10 GeV, and 17 +/- 2% at 20 GeV. | en_US |
dc.format.extent | 23909 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.extent | 633073 bytes | |
dc.format.mimetype | text/plain | |
dc.format.mimetype | text/plain | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | en_US |
dc.publisher | Elsevier | en_US |
dc.title | The performance of an L3 hadron calorimeter prototype module with BGO | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/27089/3/0000080.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0168-9002(88)90752-8 | en_US |
dc.identifier.source | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.