Show simple item record

Cochlear blood flow increases after systemic hemodilution: Comparison of simultaneous laser doppler flowmetry and radioactive microsphere measurements

dc.contributor.authorNuttall, Alfred L.en_US
dc.contributor.authorHultcrantz, Elisabethen_US
dc.contributor.authorLarsen, Hans-Christianen_US
dc.contributor.authorAngelborg, Clarenceen_US
dc.date.accessioned2006-04-07T20:14:20Z
dc.date.available2006-04-07T20:14:20Z
dc.date.issued1988-08en_US
dc.identifier.citationNuttall, Alfred L., Hultcrantz, Elisabeth, Larsen, Hans-Christian, Angelborg, Clarence (1988/08)."Cochlear blood flow increases after systemic hemodilution: Comparison of simultaneous laser doppler flowmetry and radioactive microsphere measurements." Hearing Research 34(3): 215-223. <http://hdl.handle.net/2027.42/27192>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6T73-485GDRS-2P/2/9b4a623973307ff134eb48607c23a961en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/27192
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=2459097&dopt=citationen_US
dc.description.abstractGuinea pig cochlear blood flow was measured before and after systemic normovolemic hemodilution with high molecular weight dextran. Absolute determinations of blood flow (in the cochlea, brain, kidney and lung) were accomplished by use of radioactive-labeled (85Sr or 141Ce) microspheres. Relative measurements of the cochlear blood flow changes were made simultaneously by the use of a laser Doppler flowmeter. The flowmeter probe was placed on the first cochlear turn. Hemodilution to an average systemic hematocrit of 20% increased cochlear blood flow by 250% as measured with microspheres. The laser Doppler instrument significantly underestimated the actual flow increase giving an indication of 148%. Furthermore, the data, when analyzed on an individual trial basis, showed a very poor correlation between the two methods. The theoretical basis for these findings in relation to the use of the laser Doppler instrument is discussed.en_US
dc.format.extent907683 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleCochlear blood flow increases after systemic hemodilution: Comparison of simultaneous laser doppler flowmetry and radioactive microsphere measurementsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumKresge Hearing Research Institute, Department of Otolaryngology — Head and Neck Surgery, Medical School, The University of Michigan, Ann Arbor, Michigan, U.S.A.en_US
dc.contributor.affiliationotherDepartment of Otorhinolaryngology, University Hospital, Uppsala, Swedenen_US
dc.contributor.affiliationotherDepartment of Otorhinolaryngology, University Hospital, Uppsala, Swedenen_US
dc.contributor.affiliationotherDepartment of Otorhinolaryngology, University Hospital, Uppsala, Swedenen_US
dc.identifier.pmid2459097en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/27192/1/0000195.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0378-5955(88)90001-9en_US
dc.identifier.sourceHearing Researchen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.