Anisotropic ultrasonic backscatter from the renal cortex

dc.contributor.authorRubin, Jonathan M.en_US
dc.contributor.authorCarson, Paul L.en_US
dc.contributor.authorMeyer, Charles R.en_US
dc.date.accessioned2006-04-07T20:32:42Z
dc.date.available2006-04-07T20:32:42Z
dc.date.issued1988en_US
dc.identifier.citationRubin, Jonathan M., Carson, Paul L., Meyer, Charles R. (1988)."Anisotropic ultrasonic backscatter from the renal cortex." Ultrasound in Medicine &amp; Biology 14(6): 507-511. <http://hdl.handle.net/2027.42/27571>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6TD2-4C7V9B1-G3/2/c2305301217305be2358056d979646cfen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/27571
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=3067432&dopt=citationen_US
dc.description.abstractWe have demonstrated a significant, directionally dependent, anisotropic, echogenicity from the cortices of two sheep kidneys and a normal human cadaver kidney. The anisotropy corresponds to the relationship of the sound field to the medullary rays and interlobular arteries. At 7.5 MHz, the backscatter from specimens of cortex of a sheep kidney was 4.7 +/- .7 dB (mean +/- SEM) greater in parts of the cortex where the field was perpendicular to these structures as opposed to where it was parallel to them. In addition, we measured the angular distribution of this anisotropy and compared it to the 5 dB inclusion angle of the 5 MHz linear array that was used in measurements on the whole kidney specimens. The transducer inclusion angle was 10[deg] +/- 2[deg], while the angular distribution was 34[deg] +/- 22[deg] and 23[deg] +/- 11[deg] (mean +/- SD) for the intact sheep and human kidney, respectively, demonstrating some variation of the medullary rays from perfect specular reflectors. This anisotropy should be visible in standard diagnostic scanning, and its recognition could increase ultrasound's sensitivity for the detection of renal disease.en_US
dc.format.extent549934 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleAnisotropic ultrasonic backscatter from the renal cortexen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelRadiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Radiology, University of Michigan Medical Center, Ann Arbor, MI 48109, U.S.A.en_US
dc.contributor.affiliationumDepartment of Radiology, University of Michigan Medical Center, Ann Arbor, MI 48109, U.S.A.en_US
dc.contributor.affiliationumDepartment of Radiology, University of Michigan Medical Center, Ann Arbor, MI 48109, U.S.A.en_US
dc.identifier.pmid3067432en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/27571/1/0000615.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0301-5629(88)90112-3en_US
dc.identifier.sourceUltrasound in Medicine &amp; Biologyen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.