Show simple item record

The Mark II detector for the SLC

dc.contributor.authorAbrams, G.en_US
dc.contributor.authorAdolphsen, C. E.en_US
dc.contributor.authorAkerlof, Carl W.en_US
dc.contributor.authorAlexander, J. P.en_US
dc.contributor.authorAlvarez, M.en_US
dc.contributor.authorAverill, Damon R.en_US
dc.contributor.authorBaden, A. R.en_US
dc.contributor.authorBallam, J.en_US
dc.contributor.authorBarish, B. C.en_US
dc.contributor.authorBarklow, T.en_US
dc.date.accessioned2006-05-10T15:38:35Z
dc.date.available2006-05-10T15:38:35Z
dc.date.issued1989-08-20en_US
dc.identifier.citationAbrams, G., Adolphsen, C. E., Akerlof, C., Alexander, J. P., Alvarez, M., Averill, D., Baden, A. R., Ballam, J., Barish, B. C., Barklow, T. (1989/08/20)."The Mark II detector for the SLC." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 281(1): 55-80. <http://hdl.handle.net/2027.42/27802>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6TJM-470FC8M-S6/2/b21b81372677ddbb9818f7cb961d78d7en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/27802
dc.description.abstractThe Mark II detector has been upgraded in preparation for its role as the first detector to take data at the Stanford Linear Collider. The new detector components include the central drift chamber, the time-of-flight system, the coil, the endcap electromagnetic calorimeters and the beam energy and luminosity measuring devices. There have also been improvements in detector hermeticity. All of the major components were installed for a test run at the PEP storage ring ([radical sign]s = 29 GeV) in 1985. This paper describes the upgraded detector, including its trigger and data acquisition systems, and gives performance figures for its components. Future improvements are also discussed.en_US
dc.format.extent93784 bytes
dc.format.extent3118 bytes
dc.format.extent2263086 bytes
dc.format.mimetypetext/plain
dc.format.mimetypetext/plain
dc.format.mimetypeapplication/pdf
dc.language.isoen_USen_US
dc.publisherElsevieren_US
dc.titleThe Mark II detector for the SLCen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPhysicsen_US
dc.subject.hlbsecondlevelNuclear Engineering and Radiological Sciencesen_US
dc.subject.hlbtoplevelScienceen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.contributor.affiliationotherno department founden_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/27802/3/0000202.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0168-9002(89)91217-5en_US
dc.identifier.sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.