Effect of noise, order and range in fitting the photopeak region of local, Anger-camera energy spectra

dc.contributor.authorWang, X.en_US
dc.contributor.authorKoral, Kenneth F.en_US
dc.contributor.authorClinthorne, Neal H.en_US
dc.contributor.authorRogers, W. Leslieen_US
dc.contributor.authorFloyd, Jr. , C. E.en_US
dc.contributor.authorJaszczak, R. J.en_US
dc.date.accessioned2006-04-10T13:32:00Z
dc.date.available2006-04-10T13:32:00Z
dc.date.issued1990-12-20en_US
dc.identifier.citationWang, X., Koral, K. F., Clinthorne, N. H., Rogers, W. L., Floyd, Jr., C. E., Jaszczak, R. J. (1990/12/20)."Effect of noise, order and range in fitting the photopeak region of local, Anger-camera energy spectra." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 299(1-3): 548-553. <http://hdl.handle.net/2027.42/28269>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6TJM-473FK6F-NX/2/a1cf591676574232e1a55a2426feebf3en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/28269
dc.description.abstractIn order to estimate and correct Compton scattering in nuclear-medicine Anger-camera imaging, we have previously required the least-mean-square error between the locally measured energy spectrum and one dependent on a model. The model assumes a fixed-order polynomial for the spectrum of scatter and fits the data over a specified energy range. In this study, a Monte Carlo simulation program produces spectra at specified locations in a projection image of a 99mTc "hot" sphere in a "cold" cylinder. Poisson noise is subsequently added to each spectral channel, modelling a given count level within the acceptance window. Tests were done at two pixel locations, one at the center of the sphere and the other near the edge. Without noise, we find that the calculated-to-true ratio for unscattered counts is reasonably close to 1.0 (average 1.03, range 0.85 to 1.16) for all of the 16 order-range combinations that were tested. Tests on experimental data yield comparable results. For comparison, without any Compton-scatter correction the average ratio is 1.39. Optimizing the fitting parameters is difficult because, for example, the best set for location 1 is the worst for location 2. With noisy data, the relative standard deviation, and sometimes the bias for the estimate of direct (i.e. unscattered) counts, increases as the statistical noise increases. The average relative error for the estimate is 10% for the 3 cases measured with about 5000 unscattered counts but increases to 20% if that number decreases to 700.en_US
dc.format.extent364670 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherElsevieren_US
dc.titleEffect of noise, order and range in fitting the photopeak region of local, Anger-camera energy spectraen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPhysicsen_US
dc.subject.hlbsecondlevelNuclear Engineering and Radiological Sciencesen_US
dc.subject.hlbtoplevelScienceen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Nuclear Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDivision of Nuclear Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationotherDepartment of Radiology, Duke University Medical Center, Durham, NC 27710, USAen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/28269/1/0000018.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0168-9002(90)90841-Sen_US
dc.identifier.sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.