The Silicon Vertex Detector of the Collider Detector at Fermilab
dc.contributor.author | Amidei, Dan | en_US |
dc.contributor.author | Azzi, P. | en_US |
dc.contributor.author | Bacchetta, N. | en_US |
dc.contributor.author | Bailey, M. W. | en_US |
dc.contributor.author | Barnett, B. A. | en_US |
dc.contributor.author | Bedeschi, F. | en_US |
dc.contributor.author | Bisello, D. | en_US |
dc.contributor.author | Bolognesi, V. | en_US |
dc.contributor.author | Boswell, C. | en_US |
dc.contributor.author | Busetto, G. | en_US |
dc.date.accessioned | 2006-05-10T15:38:53Z | |
dc.date.available | 2006-05-10T15:38:53Z | |
dc.date.issued | 1994-10-15 | en_US |
dc.identifier.citation | Amidei, D., Azzi, P., Bacchetta, N., Bailey, M. W., Barnett, B., Bedeschi, F., Bisello, D., Bolognesi, V., Boswell, C., Busetto, G. (1994/10/15)."The Silicon Vertex Detector of the Collider Detector at Fermilab." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 350(1-2): 73-130. <http://hdl.handle.net/2027.42/31254> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B6TJM-473FRWB-2WS/2/b6ce55689f3767b1c90cadee94a8ff21 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/31254 | |
dc.description.abstract | A silicon microstrip vertex detector has been constructed and installed in the Collider Detector at Fermilab. The device has been designed to operate at a hadron collider. It began collecting data in May of 1992 and has functioned within specification. Technical details are presented on all aspects of the system and its performance. | en_US |
dc.format.extent | 187608 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.extent | 4609624 bytes | |
dc.format.mimetype | text/plain | |
dc.format.mimetype | text/plain | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | en_US |
dc.publisher | Elsevier | en_US |
dc.title | The Silicon Vertex Detector of the Collider Detector at Fermilab | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | University of Padova, I-35100, Padova, Italy | en_US |
dc.contributor.affiliationother | The University of New Mexico, Albuquerque, NM 87131, USA | en_US |
dc.contributor.affiliationother | Purdue University, West Lafayette, IN 47907, USA | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | no department found | en_US |
dc.contributor.affiliationother | University of Padova, I-35100, Padova, Italy | en_US |
dc.contributor.affiliationother | Istituto Nazionale di Fisica Nucleare, and University and Scuola Normale Superiore of Pisa, I-56100, Pisa, Italy | en_US |
dc.contributor.affiliationother | The Johns Hopkins University, Baltimore, MD 21218, USA | en_US |
dc.contributor.affiliationother | University of Padova, I-35100, Padova, Italy | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/31254/3/0000160.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0168-9002(94)91156-8 | en_US |
dc.identifier.source | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.