An image intensifier-scintillator device for determination of profiles and images of weak beams of ionizing particles or X-rays
dc.contributor.author | Jones, Lawrence W. | en_US |
dc.contributor.author | Perl, Martin L. | en_US |
dc.date.accessioned | 2006-04-13T14:58:58Z | |
dc.date.available | 2006-04-13T14:58:58Z | |
dc.date.issued | 1961 | en_US |
dc.identifier.citation | Jones, Lawrence W., Perl, Martin L. (1961)."An image intensifier-scintillator device for determination of profiles and images of weak beams of ionizing particles or X-rays." Nuclear Instruments and Methods 10(): 348-352. <http://hdl.handle.net/2027.42/32394> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B73DN-4GX013G-27/2/76145665582983d00bf3f366619b0d9c | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/32394 | |
dc.description.abstract | An instrument for determining the shape and intensity distribution of particle and X-ray beams has been developed using an image intensifier tube together with a bundle of filaments of scintillator. A description of the use of such a device in high energy, low intensity, secondary meson and proton beams is given. It is shown that the sensitivity of this instrument represents a significant improvement over alternative techniques. | en_US |
dc.format.extent | 2055694 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | An image intensifier-scintillator device for determination of profiles and images of weak beams of ionizing particles or X-rays | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Harrison M. Randall Laboratory of Physics, The University of Michigan, Ann Arbor, Michigan, USA | en_US |
dc.contributor.affiliationum | Harrison M. Randall Laboratory of Physics, The University of Michigan, Ann Arbor, Michigan, USA | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/32394/1/0000469.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/S0029-554X(61)80131-6 | en_US |
dc.identifier.source | Nuclear Instruments and Methods | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.