A new configuration for a dipole magnet for use in high energy physics applications
dc.contributor.author | Meyer, D. I. | en_US |
dc.contributor.author | Flasck, R. | en_US |
dc.date.accessioned | 2006-04-17T15:10:59Z | |
dc.date.available | 2006-04-17T15:10:59Z | |
dc.date.issued | 1970-04-15 | en_US |
dc.identifier.citation | Meyer, D. I., Flasck, R. (1970/04/15)."A new configuration for a dipole magnet for use in high energy physics applications." Nuclear Instruments and Methods 80(2): 339-341. <http://hdl.handle.net/2027.42/32769> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B73DN-471XY2H-3FS/2/a851c46943d42003414a6f0dcfe8c29c | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/32769 | |
dc.description.abstract | The magnetic field configuration obtained when an ordinary circular solenoid is skewed looks very promising for use as a dipole magnet. The field inside is uniform and [integral operator]Bdl including end effect is independent of position across the magnet. | en_US |
dc.format.extent | 237447 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | A new configuration for a dipole magnet for use in high energy physics applications | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Physics Department, University of Michigan, Ann Arbor, Michigan 48104, U.S.A. | en_US |
dc.contributor.affiliationum | Physics Department, University of Michigan, Ann Arbor, Michigan 48104, U.S.A. | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/32769/1/0000140.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0029-554X(70)90784-6 | en_US |
dc.identifier.source | Nuclear Instruments and Methods | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.