Dynamics of gas bubbles in whole blood and plasma
dc.contributor.author | Yang, Wen-Jei | en_US |
dc.date.accessioned | 2006-04-17T16:28:42Z | |
dc.date.available | 2006-04-17T16:28:42Z | |
dc.date.issued | 1971-03 | en_US |
dc.identifier.citation | Yang, Wen-Jei (1971/03)."Dynamics of gas bubbles in whole blood and plasma." Journal of Biomechanics 4(2): 119-125. <http://hdl.handle.net/2027.42/33691> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B6T82-4C00G0P-84/2/6a3174e3ffbf99e3f044c451d662853d | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/33691 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=5119407&dopt=citation | en_US |
dc.description.abstract | Analytical solutions are obtained for both the radius-time relation and the rate of solution by diffusion of a gas bubble in plasma and whole blood with reduced hemoglobin. If an oxygen bubble is situated in the blood, a concentration boundary is formed in which the combined processes of diffusion and chemical reaction takes place. The effect of surface tension on the bubble dynamics is also considered. Applications of the analytical results include the extracorporeal oxygenation of the blood and the determination of the diffusion coefficient in plasma and the reaction velocity constant in whole blood. | en_US |
dc.format.extent | 566156 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | Dynamics of gas bubbles in whole blood and plasma | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Kinesiology and Sports | en_US |
dc.subject.hlbsecondlevel | Surgery and Anesthesiology | en_US |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Mechanical Engineering. University of Michigan, Ann Arbor. Mich. 48104, U.S.A. | en_US |
dc.identifier.pmid | 5119407 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/33691/1/0000203.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0021-9290(71)90022-4 | en_US |
dc.identifier.source | Journal of Biomechanics | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.