Equal-path time-of-flight neutron diffraction
dc.contributor.author | Carpenter, John M. | en_US |
dc.contributor.author | Sutton, John David | en_US |
dc.date.accessioned | 2006-04-17T16:51:00Z | |
dc.date.available | 2006-04-17T16:51:00Z | |
dc.date.issued | 1972-03-15 | en_US |
dc.identifier.citation | Carpenter, J. M., Sutton, J. D. (1972/03/15)."Equal-path time-of-flight neutron diffraction." Nuclear Instruments and Methods 99(3): 453-460. <http://hdl.handle.net/2027.42/34135> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B73DN-472JCWN-2W/2/4987e92ec6eea1c826f4e0665a6642bf | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/34135 | |
dc.description.abstract | Measurements of the neutron diffraction patterns of liquids and non-crystalline solids with crystal spectrometer facilities and time-of-flight diffraction techniques are discussed. It is shown that measurements with an equal-path time-of flight diffractometer generally provide the most accurate representation of a total diffraction pattern. The results of neutron diffraction measurements of vitreous silica with a crystal spectrometer and an equal-path time-of-flight diffractometer are contrasted. | en_US |
dc.format.extent | 553601 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | Equal-path time-of-flight neutron diffraction | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Nuclear Engineering and Radiological Sciences | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Nuclear Engineering, University of Michigan, Ann Arbor, Michigan 48105, U.S.A. | en_US |
dc.contributor.affiliationum | Department of Nuclear Engineering, University of Michigan, Ann Arbor, Michigan 48105, U.S.A. | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/34135/1/0000419.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0029-554X(72)90657-X | en_US |
dc.identifier.source | Nuclear Instruments and Methods | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.