Clinical applications of diffusion tensor imaging
dc.contributor.author | Dong, Qian | en_US |
dc.contributor.author | Welsh, Robert C. | en_US |
dc.contributor.author | Chenevert, Thomas L. | en_US |
dc.contributor.author | Carlos, Ruth C. | en_US |
dc.contributor.author | Maly-Sundgren, Pia | en_US |
dc.contributor.author | Gomez-Hassan, Diana M. | en_US |
dc.contributor.author | Mukherji, Suresh K. | en_US |
dc.date.accessioned | 2006-04-19T14:13:09Z | |
dc.date.available | 2006-04-19T14:13:09Z | |
dc.date.issued | 2004-01 | en_US |
dc.identifier.citation | Dong, Qian; Welsh, Robert C.; Chenevert, Thomas L.; Carlos, Ruth C.; Maly-Sundgren, Pia; Gomez-Hassan, Diana M.; Mukherji, Suresh K. (2004)."Clinical applications of diffusion tensor imaging." Journal of Magnetic Resonance Imaging 19(1): 6-18. <http://hdl.handle.net/2027.42/35153> | en_US |
dc.identifier.issn | 1053-1807 | en_US |
dc.identifier.issn | 1522-2586 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/35153 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=14696215&dopt=citation | en_US |
dc.description.abstract | Directionally-ordered cellular structures that impede water motion, such as cell membranes and myelin, result in water mobility that is also directionally-dependent. Diffusion tensor imaging characterizes this directional nature of water motion and thereby provides structural information that cannot be obtained by standard anatomic imaging. Quantitative apparent diffusion coefficients and fractional anisotropy have emerged from being primarily research tools to methods enabling valuable clinical applications. This review describes the clinical utility of diffusion tensor imaging, including the basic principles of the technique, acquisition, data analysis, and the major clinical applications. J. Magn. Reson. Imaging 2004;19:6–18. © 2003 Wiley-Liss, Inc. | en_US |
dc.format.extent | 812409 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Wiley Subscription Services, Inc., A Wiley Company | en_US |
dc.subject.other | Life and Medical Sciences | en_US |
dc.subject.other | Imaging | en_US |
dc.title | Clinical applications of diffusion tensor imaging | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Medicine (General) | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan ; University of Michigan Medical Center, Department of Radiology-MRI Division, 1500 E. Medical Center Drive, Ann Arbor, MI 48109-0030 | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, Ann Arbor, Michigan | en_US |
dc.identifier.pmid | 14696215 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/35153/1/10424_ftp.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1002/jmri.10424 | en_US |
dc.identifier.source | Journal of Magnetic Resonance Imaging | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.