dc.description.abstract | We report a case of restenosis following ostial stenting of the right coronary artery with protrusion of the stent into the aorta. Treatment was only possible after a guidewire advanced through a lower strut was used to lever the guide, and a second guidewire was advanced through the true lumen. Catheter Cardiovasc Interv 2004;62:214–217. © 2004 Wiley-Liss, Inc. | en_US |
dc.format.extent | 176596 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Wiley Subscription Services, Inc., A Wiley Company | en_US |
dc.subject.other | Life and Medical Sciences | en_US |
dc.subject.other | Cardiovascular Medicine | en_US |
dc.title | Double-wire technique for access into a protruding aorto-ostial stent for treatment of in-stent restenosis | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Medicine (General) | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Division of Cardiology, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Division of Cardiology, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, Michigan ; Division of Cardiology, University of Michigan Health System, University Hospital, TC B1-226, 1500 E Medical Center Drive, Ann Arbor, MI 48103 | en_US |
dc.identifier.pmid | 15170714 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/35258/1/20062_ftp.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1002/ccd.20062 | en_US |
dc.identifier.source | Catheterization and Cardiovascular Interventions | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.