Convective heat transfer from hightemperature air inside a tube
dc.contributor.author | Zellnik, Herbert Edmund | en_US |
dc.contributor.author | Churchill, Stuart Winston | en_US |
dc.date.accessioned | 2006-04-28T15:39:57Z | |
dc.date.available | 2006-04-28T15:39:57Z | |
dc.date.issued | 1958-03 | en_US |
dc.identifier.citation | Zellnik, Herbert E.; Churchill, Stuart W. (1958)."Convective heat transfer from hightemperature air inside a tube." AIChE Journal 4(1): 37-42. <http://hdl.handle.net/2027.42/37295> | en_US |
dc.identifier.issn | 0001-1541 | en_US |
dc.identifier.issn | 1547-5905 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/37295 | |
dc.description.abstract | Local rates of convective heat transfer from air at high temperature to a cold wall were measured in the inlet region of a circular tube. Air entered the tube with a flat velocity and temperature profile at temperatures from 480° to 2,000°F. and flow rates corresponding to Reynolds numbers from 4,500 to 22,500. The inner surface of the 1.0-in. I.D. tube was maintained at approximately 100°F. by water cooling. Local rates of heat transfer were determined at 1.5, 4, 7, and 10 tube diameters from the entrance by measuring the radial temperature profile in thermally isolated, annular sections of the tube wall. The local rate data for all gas temperatures are well represented by previous correlations for small temperature differences if the gas properties are evaluated at the bulk temperature rather than at the film temperature. The data agree well with the data of previous investigators wherever the experimental ranges overlap. | en_US |
dc.format.extent | 645370 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | American Institute of Chemical Engineers | en_US |
dc.publisher | Wiley Periodiocals, Inc. | en_US |
dc.subject.other | Chemistry | en_US |
dc.subject.other | Chemical Engineering | en_US |
dc.title | Convective heat transfer from hightemperature air inside a tube | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Chemical Engineering | en_US |
dc.subject.hlbtoplevel | Engineering | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | University of Michigan, Ann Arbor, Michigan ; Union Carbide Nuclear Company, New York, New York | en_US |
dc.contributor.affiliationum | University of Michigan, Ann Arbor, Michigan | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/37295/1/690040108_ftp.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1002/aic.690040108 | en_US |
dc.identifier.source | AIChE Journal | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.