Large area bolometers for millimeter-wave power calibration
dc.contributor.author | Rutledge, David B. | en_US |
dc.contributor.author | Ling, Curtis Chih-shan | en_US |
dc.contributor.author | Rebeiz, Gabriel M. | en_US |
dc.date.accessioned | 2006-09-11T14:57:23Z | |
dc.date.available | 2006-09-11T14:57:23Z | |
dc.date.issued | 1989-08 | en_US |
dc.identifier.citation | Rebeiz, Gabriel M.; Ling, Curtis C.; Rutledge, David B.; (1989). "Large area bolometers for millimeter-wave power calibration." International Journal of Infrared and Millimeter Waves 10(8): 931-936. <http://hdl.handle.net/2027.42/44543> | en_US |
dc.identifier.issn | 0195-9271 | en_US |
dc.identifier.issn | 1572-9559 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/44543 | |
dc.description.abstract | An accurate monolithic power meter has been developed for millimeter-wave applications. The detector is a large-area Bismuth bolometer, integrated on a fused-Quartz substrate. It simply measures the temperature change caused by the absorption of millimeter-wave radiation. The power meter is simple to fabricate, inexpensive, and can be easily calibrated using a low-frequency network. The measured responsivity for a 50Ω bolometer, with an area of 1×1cm, at a bias of 1V. and a video modulation of 100Hz, is 1mV/W. The noise spectrum exhibits a 1/f rolloff till 1KHz, and is limited by the Johnson noise for higher frequencies. The NEP of the detector is 3μWHz −1/2 at a video modulation of 1KHz. It is possible to decrease the current NEP by fabricating bolometers with higher responsivities. Possible application areas are absolute power calibration and localized power density measurements at millimeter and submillimeter wavelengths. | en_US |
dc.format.extent | 282529 bytes | |
dc.format.extent | 3115 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Kluwer Academic Publishers-Plenum Publishers; Plenum Publishing Corporation ; Springer Science+Business Media | en_US |
dc.subject.other | Astronomy | en_US |
dc.subject.other | Physics | en_US |
dc.subject.other | Meteorology/Climatology | en_US |
dc.subject.other | Electronic and Computer Engineering | en_US |
dc.title | Large area bolometers for millimeter-wave power calibration | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbsecondlevel | Mathematics | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Electrical Engineering and Computer Science Department, The University of Michigan, 48109, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationum | Electrical Engineering and Computer Science Department, The University of Michigan, 48109, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationother | Division of Engineering and Applied Science, California Institute of Technology, 91125, Pasadena, California | en_US |
dc.contributor.affiliationumcampus | Ann Arbor | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/44543/1/10762_2005_Article_BF01010389.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1007/BF01010389 | en_US |
dc.identifier.source | International Journal of Infrared and Millimeter Waves | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.