Show simple item record

Effect of General Anesthesia on the Defibrillation Energy Requirement in Patients Undergoing Defibrillator Implantation

dc.contributor.authorKnight, Bradley P.en_US
dc.contributor.authorPelosi, Frank Jr.en_US
dc.contributor.authorFlemming, Matthewen_US
dc.contributor.authorMorady, Freden_US
dc.contributor.authorStrickberger, S. Adamen_US
dc.date.accessioned2006-09-11T17:41:53Z
dc.date.available2006-09-11T17:41:53Z
dc.date.issued1999-12en_US
dc.identifier.citationKnight, Bradley P.; Pelosi, Frank; Flemming, Matthew; Morady, Fred; Strickberger, S. Adam; (1999). "Effect of General Anesthesia on the Defibrillation Energy Requirement in Patients Undergoing Defibrillator Implantation." Journal of Interventional Cardiac Electrophysiology 3(4): 325-328. <http://hdl.handle.net/2027.42/46367>en_US
dc.identifier.issn1383-875Xen_US
dc.identifier.issn1572-8595en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/46367
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=10525247&dopt=citationen_US
dc.description.abstractBackground: The effect of general anesthesia on defibrillation efficacy in humans is not known. The purpose of this study was to determine the effect of general anesthesia on the defibrillation energy requirements in patients undergoing implantation of a pectoral defibrillator.en_US
dc.format.extent73365 bytes
dc.format.extent3115 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherKluwer Academic Publishers; Springer Science+Business Mediaen_US
dc.subject.otherMedicine & Public Healthen_US
dc.subject.otherCardiologyen_US
dc.subject.otherAnesthesiaen_US
dc.subject.otherDefibrillationen_US
dc.titleEffect of General Anesthesia on the Defibrillation Energy Requirement in Patients Undergoing Defibrillator Implantationen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelInternal Medicine and Specialtiesen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumThe Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, MI; Oakwood Hospitals, Dearborn, MIen_US
dc.contributor.affiliationumThe Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, MI; Oakwood Hospitals, Dearborn, MIen_US
dc.contributor.affiliationumThe Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, MI; Oakwood Hospitals, Dearborn, MIen_US
dc.contributor.affiliationumThe Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, MI; Oakwood Hospitals, Dearborn, MIen_US
dc.contributor.affiliationumThe Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, MI; Oakwood Hospitals, Dearborn, MIen_US
dc.contributor.affiliationumcampusDearbornen_US
dc.contributor.affiliationumcampusAnn Arboren_US
dc.identifier.pmid10525247en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/46367/1/10840_2004_Article_242319.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1023/A:1009831802964en_US
dc.identifier.sourceJournal of Interventional Cardiac Electrophysiologyen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.