Direct vitreous reaction to intraocular lens implants
dc.contributor.author | Wolter, J. Reimer | en_US |
dc.date.accessioned | 2006-09-11T18:54:47Z | |
dc.date.available | 2006-09-11T18:54:47Z | |
dc.date.issued | 1983-03 | en_US |
dc.identifier.citation | Wolter, J. Reimer; (1983). "Direct vitreous reaction to intraocular lens implants." Graefe's Archive for Clinical and Experimental Ophthalmology 220(3): 110-116. <http://hdl.handle.net/2027.42/47381> | en_US |
dc.identifier.issn | 0721-832X | en_US |
dc.identifier.issn | 1435-702X | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/47381 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=6852550&dopt=citation | en_US |
dc.description.abstract | Three intraocular lens implants removed during keratoplasty between 1 1/2 and 5 years after implantation revealed attachments of reactive vitreous strands and membranes. These strands and membranes contained bundles of fibers with associated small bipolar cells, pigment, and blood remnants. Some of the fibrous vitreous strands were wound around the haptics of the implants for firm anchoring. The usual reactive cell membranes on the surface of the implants were interrupted in the areas of the attachment of formed vitreous and vitreous membranes. Drei intraokuläre Linsen, die zwischen 1 1/2 und 5 Jahre nach der Implantation während Hornhautverpflanzungen entfernt wurden, zeigten fest anheftende reaktive Glaskörperstränge und verdickte Membranen. Diese enthielten Faserbündel mit zugehörigen kleinen bipolaren Zellen, Pigment und Blutresten. Einige dieser fibrösen Glaskörperstränge waren um die Haptik der Linsenprothesen herumgewunden und damit fest verankert. Die regulären Zellmembranen auf der Oberfläche der Linsenprothesen waren im Bereich der Verbindung mit geformtem Glaskörper und Glaskörpermembranen unterbrochen. | en_US |
dc.format.extent | 4692166 bytes | |
dc.format.extent | 3115 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Springer-Verlag; Springer-Verlag GmbH & Co. KG | en_US |
dc.subject.other | Ophthalmology | en_US |
dc.subject.other | Medicine & Public Health | en_US |
dc.title | Direct vitreous reaction to intraocular lens implants | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Ophthalmology | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | The Department of Ophthalmology of the, University of Michigan Hospitals, Ann Arbor, Michigan, USA; The Department of Pathology of the, University of Michigan Hospitals, Ann Arbor, Michigan, USA | en_US |
dc.contributor.affiliationumcampus | Ann Arbor | en_US |
dc.identifier.pmid | 6852550 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/47381/1/417_2005_Article_BF02175942.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1007/BF02175942 | en_US |
dc.identifier.source | Graefe's Archive for Clinical and Experimental Ophthalmology | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.