Show simple item record

Direct vitreous reaction to intraocular lens implants

dc.contributor.authorWolter, J. Reimeren_US
dc.date.accessioned2006-09-11T18:54:47Z
dc.date.available2006-09-11T18:54:47Z
dc.date.issued1983-03en_US
dc.identifier.citationWolter, J. Reimer; (1983). "Direct vitreous reaction to intraocular lens implants." Graefe's Archive for Clinical and Experimental Ophthalmology 220(3): 110-116. <http://hdl.handle.net/2027.42/47381>en_US
dc.identifier.issn0721-832Xen_US
dc.identifier.issn1435-702Xen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/47381
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=6852550&dopt=citationen_US
dc.description.abstractThree intraocular lens implants removed during keratoplasty between 1 1/2 and 5 years after implantation revealed attachments of reactive vitreous strands and membranes. These strands and membranes contained bundles of fibers with associated small bipolar cells, pigment, and blood remnants. Some of the fibrous vitreous strands were wound around the haptics of the implants for firm anchoring. The usual reactive cell membranes on the surface of the implants were interrupted in the areas of the attachment of formed vitreous and vitreous membranes. Drei intraokuläre Linsen, die zwischen 1 1/2 und 5 Jahre nach der Implantation während Hornhautverpflanzungen entfernt wurden, zeigten fest anheftende reaktive Glaskörperstränge und verdickte Membranen. Diese enthielten Faserbündel mit zugehörigen kleinen bipolaren Zellen, Pigment und Blutresten. Einige dieser fibrösen Glaskörperstränge waren um die Haptik der Linsenprothesen herumgewunden und damit fest verankert. Die regulären Zellmembranen auf der Oberfläche der Linsenprothesen waren im Bereich der Verbindung mit geformtem Glaskörper und Glaskörpermembranen unterbrochen.en_US
dc.format.extent4692166 bytes
dc.format.extent3115 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherSpringer-Verlag; Springer-Verlag GmbH & Co. KGen_US
dc.subject.otherOphthalmologyen_US
dc.subject.otherMedicine & Public Healthen_US
dc.titleDirect vitreous reaction to intraocular lens implantsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelOphthalmologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumThe Department of Ophthalmology of the, University of Michigan Hospitals, Ann Arbor, Michigan, USA; The Department of Pathology of the, University of Michigan Hospitals, Ann Arbor, Michigan, USAen_US
dc.contributor.affiliationumcampusAnn Arboren_US
dc.identifier.pmid6852550en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/47381/1/417_2005_Article_BF02175942.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1007/BF02175942en_US
dc.identifier.sourceGraefe's Archive for Clinical and Experimental Ophthalmologyen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.