RF Pulse Design for Parallel Excitation in MRI.

dc.contributor.authorGrissom, William Allynen_US
dc.date.accessioned2008-05-08T19:18:31Z
dc.date.availableNO_RESTRICTIONen_US
dc.date.available2008-05-08T19:18:31Z
dc.date.issued2008en_US
dc.date.submitteden_US
dc.identifier.urihttps://hdl.handle.net/2027.42/58521
dc.description.abstractParallel excitation in MRI uses localized coils driven by independent RF waveforms as a mechanism for spatially encoding RF energy deposition. Because localized coil (or sensitivity) encoding is imposed instantaneously, one can create shorter pulses by trading gradient encoding for sensitivity encoding. However, the parallel pulse design problem is complicated by the non-Fourier nature of sensitivity encoding and the potential for patient-dependent problem inputs, requiring pulses to be designed rapidly online. In this project, I investigate novel techniques for parallel RF pulse design, with a focus on fast and general methods. I first propose a model-based iterative small-tip-angle pulse design method that is facilitated by a linear Fourier analysis of small-tip-angle excitation. It allows the user to rapidly design pulses with compensation for non-idealities such as main field inhomogeneities. We show in simulations and experiments that it produces pulses of higher accuracy than competing methods. The non-linear large-tip-angle regime requires more complex pulse design methods. To address this problem, I also investigate two fast large-tip-angle pulse design methods. Both are formulated as a series of Bloch simulations interleaved with small-tip-angle pulse designs whose results sum to produce accurate large-tip-angle pulses. Small-tip-angle pulse designs use approximate linear models for the perturbations induced by adding a small-tip-angle pulse to a large-tip-angle pulse. The first method uses the Fourier small-tip-angle equation as a linear model. We demonstrate that it is fast, robust and simple to implement, but it has some drawbacks, such as the inability to control excitation phase, that are addressed by the second method. The second method is based on a novel analytical linearization of the Bloch equation about an RF pulse. While more complex than the first method, we show that it produces pulses of higher accuracy, and can be applied to a broader range of pulse design problems. Both methods produce large-tip-angle pulses of higher accuracy than small-tip-designed pulses that are scaled to produce large-tip-angles.en_US
dc.format.extent3314355 bytes
dc.format.extent1373 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_USen_US
dc.subjectMRIen_US
dc.subjectParallel Excitationen_US
dc.subjectRF Pulse Designen_US
dc.subjectK-spaceen_US
dc.subjectLarge-tip-Angleen_US
dc.titleRF Pulse Design for Parallel Excitation in MRI.en_US
dc.typeThesisen_US
dc.description.thesisdegreenamePhDen_US
dc.description.thesisdegreedisciplineBiomedical Engineeringen_US
dc.description.thesisdegreegrantorUniversity of Michigan, Horace H. Rackham School of Graduate Studiesen_US
dc.contributor.committeememberNoll, Douglas C.en_US
dc.contributor.committeememberChenevert, Thomas L.en_US
dc.contributor.committeememberFessler, Jeffrey A.en_US
dc.contributor.committeememberMichielssen, Ericen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/58521/1/wgrissom_1.pdf
dc.owningcollnameDissertations and Theses (Ph.D. and Master's)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.