Show simple item record

Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging

dc.contributor.authorHan, Lien_US
dc.contributor.authorRogers, W. Leslieen_US
dc.contributor.authorHuh, Sam S.en_US
dc.contributor.authorClinthorne, Neal H.en_US
dc.date.accessioned2009-10-08T15:30:42Z
dc.date.available2009-10-08T15:30:42Z
dc.date.issued2008en_US
dc.identifier.citationHan, Li; Rogers, W Leslie; Huh, Sam S; Clinthorne, Neal (2008). "Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging." Physics in Medicine and Biology 53(24):7029-7045. <http://hdl.handle.net/2027.42/64143>en_US
dc.identifier.issn0031-9155en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/64143
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=19015578&dopt=citationen_US
dc.description.abstract"In radionuclide treatment, tumor cells are primarily destroyed by charged particles emitted by the compound while associated higher energy photons are used to image the tumor in order to determine radiation dose and monitor shrinkage. However, the higher energy photons are difficult to image with conventional collimated Anger cameras, since a tradeoff exists between resolution and sensitivity, and the collimator septal penetration and scattering is increased due to the high energy photons. This research compares imaging performance of the conventional Anger camera to a Compton imaging system that can have improved spatial resolution and sensitivity for high energy photons because this tradeoff is decoupled, and the effect of Doppler broadening at higher gamma energies is decreased. System performance is analyzed by the modified uniform Cramer-Rao bound (M-UCRB) algorithms based on the developed system modeling. The bound shows that the effect of Doppler broadening is the limiting factor for Compton camera performance for imaging 364.4 keV photons emitted from 131I. According to the bound, the Compton camera outperforms the collimated system for an equal number of detected events when the desired spatial resolution for a 26 cm diameter uniform disk object is better than 12 mm FWHM. For a 3D cylindrical phantom, the lower bound on variance for the collimated camera is greater than for the Compton imaginer over the resolution range from 0.5 to 2 cm FWHM. Furthermore, the detection sensitivity of the proposed Compton imaging system is about 15-20 times higher than that of the collimated Anger camera."en_US
dc.format.extent1088031 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.titleStatistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imagingen_US
dc.typeArticleen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.identifier.pmid19015578en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/64143/1/pmb8_24_002.pdf
dc.identifier.doihttp://dx.doi.org/10.1088/0031-9155/53/24/002en_US
dc.identifier.sourcePhysics in Medicine and Biologyen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.