Show simple item record

Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media

dc.contributor.authorTyagi, N.en_US
dc.contributor.authorCurran, B. H.en_US
dc.contributor.authorRoberson, Peter L.en_US
dc.contributor.authorMoran, Jean M.en_US
dc.contributor.authorAcosta, E.en_US
dc.contributor.authorFraass, Benedick A.en_US
dc.date.accessioned2009-10-08T15:35:06Z
dc.date.available2009-10-08T15:35:06Z
dc.date.issued2008en_US
dc.identifier.citationTyagi, N; Curran, B H; Roberson, P L; Moran, J M; Acosta, E; Fraass, B A (2008). "Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media." Journal of Physics: Conference Series 102():012025 (8pp). <http://hdl.handle.net/2027.42/64219>en_US
dc.identifier.issn1742-6588en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/64219
dc.description.abstract"IMRT often requires delivering small fields which may suffer from electronic disequilibrium effects. The presence of heterogeneities, particularly low-density tissues in patients, complicates such situations. In this study, we report on verification of the DPM MC code for IMRT treatment planning in heterogeneous media, using a previously developed model of the Varian 120-leaf MLC. The purpose of this study is twofold: (a) design a comprehensive list of experiments in heterogeneous media for verification of any dose calculation algorithm and (b) verify our MLC model in these heterogeneous type geometries that mimic an actual patient geometry for IMRT treatment. The measurements have been done using an IMRT head and neck phantom (CIRS phantom) and slab phantom geometries. Verification of the MLC model has been carried out using point doses measured with an A14 slim line (SL) ion chamber inside a tissue-equivalent and a bone-equivalent material using the CIRS phantom. Planar doses using lung and bone equivalent slabs have been measured and compared using EDR films (Kodak, Rochester, NY)."en_US
dc.format.extent1149484 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.titleExperimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous mediaen_US
dc.typeArticleen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/64219/1/jpconf8_102_012025.pdf
dc.identifier.doihttp://dx.doi.org/10.1088/1742-6596/102/1/012025en_US
dc.identifier.sourceJournal of Physics: Conference Seriesen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.