Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septal Defect Closure
dc.contributor.author | Minich, L. LuAnn | en_US |
dc.contributor.author | Snider, A. Rebecca | en_US |
dc.date.accessioned | 2010-06-01T18:20:45Z | |
dc.date.available | 2010-06-01T18:20:45Z | |
dc.date.issued | 1993-11 | en_US |
dc.identifier.citation | MINICH, L. LUANN; SNIDER, A. REBECCA (1993). "Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septal Defect Closure." Echocardiography 10(6): 567-572. <http://hdl.handle.net/2027.42/71555> | en_US |
dc.identifier.issn | 0742-2822 | en_US |
dc.identifier.issn | 1540-8175 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/71555 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=10146448&dopt=citation | en_US |
dc.format.extent | 1670183 bytes | |
dc.format.extent | 3109 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.publisher | Blackwell Publishing Ltd | en_US |
dc.rights | 1993 Futura Publishing Co., Inc. | en_US |
dc.subject.other | Doppler Ultrasound | en_US |
dc.subject.other | Two-dimensional Echocardiography | en_US |
dc.subject.other | Atrial Septal Defect | en_US |
dc.subject.other | Cardiac Catheterization | en_US |
dc.subject.other | Transesophageal Echocardiography | en_US |
dc.title | Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septal Defect Closure | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Pediatrics, C.S. Mott Children's Hospital, University of Michigan Medical Center, Ann Arbor, Michigan | en_US |
dc.identifier.pmid | 10146448 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/71555/1/j.1540-8175.1993.tb00072.x.pdf | |
dc.identifier.doi | 10.1111/j.1540-8175.1993.tb00072.x | en_US |
dc.identifier.source | Echocardiography | en_US |
dc.identifier.citedreference | Hellenbrand WE, Fahey JT, McGowan FX, et al: Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 1990; 66: 207 – 213. | en_US |
dc.identifier.citedreference | Stumper O, Witsenburg M, Sutherland GR, et al: Transesophageal echocardiographic monitoring of interventional cardiac catheterization in children. J Am Coll Cardiol 1991; 18: 1506 – 1514. | en_US |
dc.identifier.citedreference | Sideris EB, Sideris SE, Fowlkes JP, et al: Transvenous atrial septal defect occlusion in piglets with a “buttoned” double-disk device. Circulation 1990; 81: 312 – 318. | en_US |
dc.identifier.citedreference | Sideris EB, Sideris SE, Thanopoulos BD, et al: Transvenous atrial septal defect occlusion by the buttoned device. Am J Cardiol 1990; 66: 1524 – 1526. | en_US |
dc.identifier.citedreference | Rao PS, Wilson AD, Levy JM, et al: Role of “buttoned” double-disc device in the management of atrial septal defects. Am J Cardiol 1992; 123: 191 – 200. | en_US |
dc.identifier.citedreference | Rao PD, Wilson AD, Chopra PS: Transcatheter closure of atrial septal defect by “buttoned” devices. Am J Cardiol 1992; 69: 1056 – 1061. | en_US |
dc.identifier.citedreference | King TD, Thompson SL, Mills NL: Measurement of atrial septal defect during cardiac catheterization: Experimental and clinical results. Am J Cardiol 1978; 41: 537 – 542. | en_US |
dc.identifier.citedreference | Rao PS, Langhough R: Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J 1991; 122: 505 – 508. | en_US |
dc.identifier.citedreference | Shub C, Dimopoulos IN, Seward JB, et al: Sensitivity of two-dimensional echocardiography in the direct visualization of atrial septal defect utilizing the subcostal approach: Experience with 154 patients. J Am Coll Cardiol 1983; 2: 127 – 135. | en_US |
dc.identifier.citedreference | Khandheria BK, Shub C, Tajik AJ, et al: Utility of color flow imaging for visualizing shunt flow in atrial septal defect. Int J Cardiol 1989; 23: 91 – 98. | en_US |
dc.identifier.citedreference | Mehta RH, Helmcke F, Nanda NC, et al: Transesophageal Doppler color flow mapping assessment of atrial septal defect. J Am Coll Cardiol 1990; 16: 1010 – 1016. | en_US |
dc.identifier.citedreference | Pearson AC, Labovitz AJ, Tatineni S, et al: Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991; 17: 66 – 72. | en_US |
dc.identifier.citedreference | Kronzon I, Tunick PA, Freedberg RS, et al: Transesophageal echocardiography is superior to transthoracic echocardiography in the diagnosis of sinus venosus atrial septal defect. J Am Coll Cardiol 1991; 17: 537 – 542. | en_US |
dc.identifier.citedreference | Stumper O, Kaulitz R, Elzenga NJ, et al: The value of transesophageal echocardiography in children with congenital heart disease. J Am Soc Echocardiogr 1991; 4: 164 – 176. | en_US |
dc.identifier.citedreference | Ritter SB: Transesophageal real-time echocardiography in infants and children with congenital heart disease. J Am Coll Cardiol 1991; 18: 569 – 580. | en_US |
dc.identifier.citedreference | Pearson AC, Nagelhout D, Castello R, et al: Atrial septal aneurysm and stroke: A transesophageal echocardiographic study. J Am Coll Cardiol 1991; 18: 1223 – 1229. | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.