Effect of Basic Drive Train Cycle Length on Induction of Ventricular Tachycardia by a Single Extrastimulus
dc.contributor.author | Morady, Fred | en_US |
dc.contributor.author | Kou, William H. | en_US |
dc.contributor.author | Kadish, Alan H. | en_US |
dc.contributor.author | Schmaltz, Stephen P. | en_US |
dc.contributor.author | Summitt, Joni | en_US |
dc.contributor.author | Rosenheck, Shimon | en_US |
dc.date.accessioned | 2010-06-01T18:25:44Z | |
dc.date.available | 2010-06-01T18:25:44Z | |
dc.date.issued | 1989-04 | en_US |
dc.identifier.citation | MORADY, FRED; KOU, WILLIAM H.; KADISH, ALAN H.; SCHMALTZ, STEPHEN; SUMMITT, JONI; ROSENHECK, SHIMON (1989). "Effect of Basic Drive Train Cycle Length on Induction of Ventricular Tachycardia by a Single Extrastimulus." Journal of Cardiovascular Electrophysiology 3(2): 111-116. <http://hdl.handle.net/2027.42/71636> | en_US |
dc.identifier.issn | 1045-3873 | en_US |
dc.identifier.issn | 1540-8167 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/71636 | |
dc.format.extent | 423433 bytes | |
dc.format.extent | 3109 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.publisher | Blackwell Publishing Ltd | en_US |
dc.rights | 1989 Futura Publishing Company, Inc. | en_US |
dc.subject.other | Programmed Ventricular Stimulation | en_US |
dc.subject.other | Ventricular Tachycardia | en_US |
dc.title | Effect of Basic Drive Train Cycle Length on Induction of Ventricular Tachycardia by a Single Extrastimulus | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | en_US |
dc.subject.hlbsecondlevel | Physiology | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Division of Cardiology and the Clinical Research Center, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/71636/1/j.1540-8167.1989.tb01538.x.pdf | |
dc.identifier.doi | 10.1111/j.1540-8167.1989.tb01538.x | en_US |
dc.identifier.source | Journal of Cardiovascular Electrophysiology | en_US |
dc.identifier.citedreference | Doherty JU, Kienzle MG, Waxman HL, et al.: Relation of mode of induction and cycle length of ventricular tachycardia: analysis of 104 patients. Am J Cardiol, 52: 60, 1983. | en_US |
dc.identifier.citedreference | Mann DE, Luck JE, Griffin JC, et al.: Induction of clinical ventricular tachycardia using programmed stimulation: value of third and fourth extrastimuli. Am J Cardiol, 52: 501, 1983. | en_US |
dc.identifier.citedreference | Doherty DU, Kienzle MG, Waxman HL, et al.: Programmed ventricular stimulation at a second right ventricular site: an analysis of 100 patients, with special reference to sensitivity, specificity, and characteristics of patients with induced ventricular tachycardia. Am J Cardiol, 52: 1184, 1983. | en_US |
dc.identifier.citedreference | Buxton AE, Waxman HL, Marchlinski FE: Role of triple extrastimuli during electrophysiological study of patients with documented sustained ventricular tachyarrhythmias. Circulation 69 ( 3 ): 532, 1984. | en_US |
dc.identifier.citedreference | Morady F, DiCarlo L, Winston S, et al.: A prospective comparison of triple extrastimuli and left ventricular stimulation in studies of ventricular tachycardia induction. Circulation 70 ( 1 ): 52, 1984. | en_US |
dc.identifier.citedreference | Brugada P, Wellens HJJ: Comparsion in the same patient of two programmed ventricular stimulation protocols to induce ventricular tachycardia. Am J Cardiol, 55: 380, 1985. | en_US |
dc.identifier.citedreference | Herre JM, Mann DE, Luck JC, et al.: Effect of increased current, multiple pacing sites and number of extrastimuli on induction of ventricular tachycardia. Am J Cardiol, 57: 102, 1986. | en_US |
dc.identifier.citedreference | Morady F, DiCarlo LA, Baerman JM, et al.: Comparison of coupling intervals that induce clinical and nonclinical forms of ventricular tachycardia during programmed stimulation. Am J Cardiol, 57: 1269, 1986. | en_US |
dc.identifier.citedreference | Lin HT, Mann DE, Luctk JC, et al.: Prospective comparison of right and left ventricular stimulation for induction of sustained ventricular tachycardia. Am J Cardiol, 59: 559, 1987. | en_US |
dc.identifier.citedreference | Estes M, Garan H, McGovern B, et al.: Influence of drive cycle length during programmed stimulation on induction of ventricular arrhythmias: analysis of 403 patients. Am J Cardiol, 57: 108, 1986. | en_US |
dc.identifier.citedreference | Schluchter MD: BMDP 5V-unbalanced repeated measures models with structured covariance matrices. 86: 29, 1988. | en_US |
dc.identifier.citedreference | Freeman DH, Applied Categorical Data Analysis. New York: Marcel Dekker, Inc. pp 237 – 274, 1987. | en_US |
dc.identifier.citedreference | Breithardt G, Borggrefe M, Podczeck A, et al.: Influence of the cycle length of basic drive on induction of sustained ventricular tachycardia associated with coronary artery disease. Am J Cardiol, 60: 1306, 1987. | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.