Show simple item record

Comparison of Fixed Burst Versus Decremental Burst Pacing for Termination of Ventricular Tachycardia

dc.contributor.authorCalkins, Hugh G.en_US
dc.contributor.authorEl-Atassi, Rafelen_US
dc.contributor.authorKalbfleisch, Steven J.en_US
dc.contributor.authorLangberg, Jonathan J.en_US
dc.contributor.authorMorady, Freden_US
dc.date.accessioned2010-06-01T19:17:43Z
dc.date.available2010-06-01T19:17:43Z
dc.date.issued1993-01en_US
dc.identifier.citationCALKINS, HUGH; EL-ATASSI, RAFEL; KALBFLEISCH, STEVE; LANGBERG, JONATHAN; MORADY, FRED (1993). "Comparison of Fixed Burst Versus Decremental Burst Pacing for Termination of Ventricular Tachycardia." Pacing and Clinical Electrophysiology 16(1): 26-32. <http://hdl.handle.net/2027.42/72440>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/72440
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=7681171&dopt=citationen_US
dc.format.extent2926314 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1993 Official journal of the International Cardiac Pacing and Electrophysiology Societyen_US
dc.titleComparison of Fixed Burst Versus Decremental Burst Pacing for Termination of Ventricular Tachycardiaen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumUniversity of Michigan Medical Center Division of Cardiology, Ann Arbor, Michiganen_US
dc.identifier.pmid7681171en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/72440/1/j.1540-8159.1993.tb01531.x.pdf
dc.identifier.doi10.1111/j.1540-8159.1993.tb01531.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceHerre JM, Cannom DS, Fogoros RN, et al. Initial multicenter clinical experience with a multifunctional implantable pacemaker defihrillator. Circulation 1991; 84: 11 – 428.en_US
dc.identifier.citedreferenceEllenbogen K, Luceri R, Dorian P, et al. Clinical evaluation of implantable cardioverter defibrillator (ICD) function: Importance of data logging to assess device efficacy. Circulation 1991; 84: 11 – 426.en_US
dc.identifier.citedreferenceRankin AC, Zaim S, Powell A, et al. Efficacy and limitation of tiered therapy for the treatment of recurrent ventricular arrhythmias. Circulation 1991; 84: II-427.en_US
dc.identifier.citedreferenceCharos GS, Haffajee CI, Gold RL, et al. A theoretically and practically more effective method for interruption of ventricular tachycardia: Self-adapting autodecremental overdrive pacing. Circulation 1986; 73: 309 – 315.en_US
dc.identifier.citedreferenceRoy D, Waxman HL, Buxton AE, et al. Termination of ventricular tachycardia: Role of tachycardia cycle length. Am J Cardiol 1982; 50: 1346 – 1350.en_US
dc.identifier.citedreferenceNaccarelli GV, Zipes DP, Rahilly T, et al. Influence of tachycardia cycle length and antiarrhythmic drugs on pacing termination and acceleration of ventricular tachycardia. Am Heart J 1983; 1: 1 – 5.en_US
dc.identifier.citedreferenceFisher JD, Mehra R, Furman S. Termination of ventricular tachycardia with bursts of rapid ventricular pacing. Am J Cardiol 1978; 41: 94 – 101.en_US
dc.identifier.citedreferenceFisher JD, Kim SG, Matos JA, et al. Comparative effectiveness of pacing techniques for termination of well-tolerated sustained ventricular tachycardia. PACE 1983; 6: 915 – 922.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.