Show simple item record

The present and future crossmatch

dc.contributor.authorOberman, Harold A.en_US
dc.date.accessioned2010-06-01T19:40:19Z
dc.date.available2010-06-01T19:40:19Z
dc.date.issued1992-11-12en_US
dc.identifier.citationOBERMAN, HAROLD A. (1992). "The present and future crossmatch." Transfusion 32(9): 794-796. <http://hdl.handle.net/2027.42/72806>en_US
dc.identifier.issn0041-1132en_US
dc.identifier.issn1537-2995en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/72806
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=1471241&dopt=citationen_US
dc.format.extent241790 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Science Ltden_US
dc.rights1992 AABBen_US
dc.titleThe present and future crossmatchen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelOncology and Hematologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumProfessor of Pathology Director of Blood Bank and Transfusion Service University of Michigan Medical Center 1500 East Medical Center Drive Ann Arbor, MI 48109en_US
dc.identifier.pmid1471241en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/72806/1/j.1537-2995.1992.32993110747.x.pdf
dc.identifier.doi10.1046/j.1537-2995.1992.32993110747.xen_US
dc.identifier.sourceTransfusionen_US
dc.identifier.citedreferenceOberman HA. The crossmatch: a brief historical perspective. Transfusion 1981; 21: 645 – 51.en_US
dc.identifier.citedreferenceGarratty G. Abbreviated pretransfusion testing (editorial). Transfusion 1986; 26: 217 – 9.en_US
dc.identifier.citedreferenceBove JR, Cedergren B., Davey RJ, et al. Do you think that the crossmatch with donor red cells can be omitted when the serum of a patient has been tested for the presence of red cell alloanti-bodies with a cell panel? Vox Sang 1982; 43: 151 – 68.en_US
dc.identifier.citedreferenceOberman HA, Barnes BA, Friedman BA. The risk of abbreviating the major crossmatch in urgent or massive transfusion. Transfusion 1978; 18: 137 – 41.en_US
dc.identifier.citedreferenceOberman HA, Barnes BA, Steiner EA. Role of the crossmatch in testing for serologic incompatibility. Transfusion 1982; 22: 12 – 6.en_US
dc.identifier.citedreferenceMintz PD, Haines AL, Sullivan MF. Incompatible crossmatch following nonreactive antibody detection test Frequency and cause. Transfusion 1982; 22: 107 – 10.en_US
dc.identifier.citedreferenceLamberson RD, Boral LI, Berry-Dortch S. Limitations of the crossmatch for detection of incompatibility between A2B red blood cells and B patient sera. Am J Clin Pathol 1986; 86: 511 – 3.en_US
dc.identifier.citedreferenceBerry-Dortch S., Woodside CH, Boral LI. Limitations of the immediate spin crossmatch when used for detecting ABO incompatibility. Transfusion 1985; 25: 176 – 8.en_US
dc.identifier.citedreferenceJudd WJ, Steiner EA, O'Donnell DB, Oberman HA. Discrepancies in reverse ABO typing due to prozone: how safe is the immediate-spin crossmatch? Transfusion 1988; 28: 334 – 8.en_US
dc.identifier.citedreferenceJudd WJ, Steiner EA, Abruzzo LV, et al. Anti-i causing acute hemolysis following a negative immediate-spin crossmatch. Transfusion 1992; 32: 572 – 5.en_US
dc.identifier.citedreferenceReznicek MJ, Cordle DG, Strauss RG. A hemolytic reaction implicating Sda antibody missed by immediate spin crossmatch. Vox Sang 1992; 62: 173 – 5.en_US
dc.identifier.citedreferencePinkerton PH, Coovadia AS, Goldstein J. Frequency of delayed hemolytic transfusion reactions following antibody screening and immediate-spin crossmatching. Transfusion 1992; 32: 814 – 7.en_US
dc.identifier.citedreferenceCordle DG, Strauss RG, Snyder EL, Floss AM. Safety and cost-containment data that advocate abbreviated pretransfusion testing. Am J Clin Pathol 1990; 94: 428 – 31.en_US
dc.identifier.citedreferenceShulman IA. The risk of an overt hemolytic transfusion reaction following the use of an immediate spin crossmatch. Arch Pathol Lab Med 1990; 114: 412 – 4.en_US
dc.identifier.citedreferenceWidmann FK, ed. Standards for blood banks and transfusion services. 14th ed. Arlington: American Association of Blood Banks, 1991.en_US
dc.identifier.citedreferenceButch SH, Judd WJ, Steiner EA, Stoe M., Oberman HA. The computer crossmatch (abstract #S-11). To be presented at the 45th Annual Meeting of the American Association of Blood Banks, San Francisco, CA, November 1992.en_US
dc.identifier.citedreferenceJudd WJ. Are there better ways than the crossmatch to demonstrate ABO incompatibility? (editorial). Transfusion 1991; 31: 192 – 4.en_US
dc.identifier.citedreferenceWinn LC, Svoboda R., Hafleigh EB, Grumet FC. An extended antibody screen to replace the crossmatch. Presented at the 33rd Annual Meeting of the American Association of Blood Banks, Washington, DC, 1980.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.