A Comparison of QRS Complexes Resulting From Unipolar and Bipolar Pacing: Implications for Pace-Mapping

dc.contributor.authorKadish, Alan H.en_US
dc.contributor.authorSchmaltz, Stevenen_US
dc.contributor.authorMorady, Freden_US
dc.date.accessioned2010-06-01T20:14:59Z
dc.date.available2010-06-01T20:14:59Z
dc.date.issued1991-05en_US
dc.identifier.citationKADISH, ALAN H.; SCHMALTZ, STEVE; MORADY, FRED (1991). "A Comparison of QRS Complexes Resulting From Unipolar and Bipolar Pacing: Implications for Pace-Mapping." Pacing and Clinical Electrophysiology 14(5): 823-832. <http://hdl.handle.net/2027.42/73370>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/73370
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=1712960&dopt=citationen_US
dc.format.extent777356 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1991 Official journal of the International Cardiac Pacing and Electrophysiology Societyen_US
dc.subject.otherVentricular Pacingen_US
dc.subject.otherVentricular Tachycardiaen_US
dc.subject.otherMappingen_US
dc.subject.otherPace-mappingen_US
dc.titleA Comparison of QRS Complexes Resulting From Unipolar and Bipolar Pacing: Implications for Pace-Mappingen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michiganen_US
dc.identifier.pmid1712960en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/73370/1/j.1540-8159.1991.tb04113.x.pdf
dc.identifier.doi10.1111/j.1540-8159.1991.tb04113.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceJosephson ME, Harken AH, Horowitz LN. Endocardial excision: A new surgical technique for the treatment of recurrent ventricular tachycardia. Circulation 1979; 60: 1430 – 1439.en_US
dc.identifier.citedreferenceMorady F, Scheinman MM, DiCarlo LA Jr, et al. Catheter ablation of ventricular tachycardia with intracardiac shocks: Results in 33 patients. Circulation 1987; 75: 1037 – 1049.en_US
dc.identifier.citedreferenceBrugada P, De Swart H, Smeets JLRM, et al. Trans-coronary chemical ablation of ventricular tachycardia. Circulation 1989; 79: 475 – 482.en_US
dc.identifier.citedreferenceNaccarelli GV, Kuck K-H, Pitha JV, et al. Catheter ablation of canine ventricular myocardium utilizing radiofrequency current. J Electrophysiol 1989; 3: 223 – 232.en_US
dc.identifier.citedreferenceJosephson ME, Waxman HL, Cain ME, et al. Ventricular activation during ventricular endocardial pacing. II. Role of pace-mapping to localize origin of ventricular tachycardia. J Am Coll Cardiol 1982; 50: 11 – 22.en_US
dc.identifier.citedreferenceKadish AH, Childs K, Schmaltz S, et al. Differences in QRS configuration during unipolar pacing from adjacent sites: Implications for the spatial resolution of pace-mapping. J Am Coll Cardiol ( In press ) 1991.en_US
dc.identifier.citedreferenceStevenson WG, Weiner I, Weiss JN. Contribution of the anode to ventricular excitation during bipolar programmed electrical stimulation. Am J Cardiol 1986; 57: 582 – 586.en_US
dc.identifier.citedreferenceKadish AH, Morady F, Rosenheck S, et al. The effect of electrode configuration on the unipolar His-bundle electrogram. PACE 1989; 12: 1445 – 1450.en_US
dc.identifier.citedreferenceCassidy DM, Vassallo JA, Miller JM, et al. Endocardial catheter mapping in patients in sinus rhythm: Relationship to underlying heart disease and ventricular arrhythmias. Circulation 1986; 73: 645 – 652.en_US
dc.identifier.citedreferenceStevenson WG, Weiss JN, Wiener I, et al. Fractionated endocardial electrograms are associated with slow conduction in humans: Evidence from pace-mapping. J Am Coll Cardiol 1989; 13: 369 – 376.en_US
dc.identifier.citedreferenceVan Gelder LM, El Gamal MIH, Tielen CHJ. Changes in configuration of the paced QRS complex related to pacemaker output. PACE 1989; 12: 1640 – 1649.en_US
dc.identifier.citedreferenceDekker E. Direct current make and break thresholds for pacemaker electrodes on the canine ventricle. Circ Res 1970; 27: 811 – 823.en_US
dc.identifier.citedreferenceFrazier DW, Krassowska W, Chen P, et al. Extracellular field required for excitation in three-dimensional anisotopic canine myocardium. Circ Res 1988; 63: 147 – 164.en_US
dc.identifier.citedreferenceMiller JM, Harken AH, Hargrove WC. Pattern of endocardial activation during sustained ventricular tachycardia. J Am Coll Cardiol 1985; 6: 1280 – 1287.en_US
dc.identifier.citedreferenceMehra R, Zeiler R, Gough WB, et al. Reentrant ventricular arrhythmias in the late myocardial infarction period. 9. Electrophysiologic-anatomic correlation of reentrant circuits. Circ Res 1983; 67: 11 – 24.en_US
dc.identifier.citedreferenceHarris L, Downar E, Mickleborough L, et al. Activation sequence of ventricular tachycardia: Endocardial and epicardial mapping studies in the human ventricle. J Am Coll Cardiol 1987; 10: 1040 – 1047.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.