Show simple item record

Accuracy of the Unipolar Electrogram for Identification of the Site of Origin of Ventricular Activation

dc.contributor.authorMan, K. Chingen_US
dc.contributor.authorDaoud, Emile G.en_US
dc.contributor.authorKnight, Bradley P.en_US
dc.contributor.authorBahu, Marwanen_US
dc.contributor.authorWeiss, Raulen_US
dc.contributor.authorZivin, Adamen_US
dc.contributor.authorSouza, S. Josephen_US
dc.contributor.authorGoyal, Rajivaen_US
dc.contributor.authorStrickberger, S. Adamen_US
dc.contributor.authorMorady, Ereden_US
dc.date.accessioned2010-06-01T20:46:23Z
dc.date.available2010-06-01T20:46:23Z
dc.date.issued1997-09en_US
dc.identifier.citationMAN, K. CHING; DAOUD, EMILE G.; KNIGHT, BRADLEY P.; BAHU, MARWAN; WEISS, RAUL; ZIVIN, ADAM; SOUZA, S. JOSEPH; GOYAL, RAJIVA; STRICKBERGER, S. ADAM; MORADY, ERED (1997). "Accuracy of the Unipolar Electrogram for Identification of the Site of Origin of Ventricular Activation." Journal of Cardiovascular Electrophysiology 8(9): 974-979. <http://hdl.handle.net/2027.42/73873>en_US
dc.identifier.issn1045-3873en_US
dc.identifier.issn1540-8167en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/73873
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=9300293&dopt=citationen_US
dc.format.extent2326011 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1997 Blackwell Publishing Ltden_US
dc.subject.otherCatheter Ablationen_US
dc.subject.otherUnipolar Electrogramen_US
dc.subject.otherActivation Mappingen_US
dc.subject.otherSpatial Resolutionen_US
dc.subject.otherVentricular Tachycardiaen_US
dc.titleAccuracy of the Unipolar Electrogram for Identification of the Site of Origin of Ventricular Activationen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelInternal Medicine and Specialtiesen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Cardiology. Department of internal Medicine, University of Michigan Medical Center. Ann Arbor. Michiganen_US
dc.identifier.pmid9300293en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/73873/1/j.1540-8167.1997.tb00619.x.pdf
dc.identifier.doi10.1111/j.1540-8167.1997.tb00619.xen_US
dc.identifier.sourceJournal of Cardiovascular Electrophysiologyen_US
dc.identifier.citedreferenceHaissaguerre M, Dartigues JF, Warin JF, et al: Electrogram patterns predictive of successful catheter ablation of accessory pathways. Circulation 1991; 84: 188 – 202.en_US
dc.identifier.citedreferencePoty H, Saoudi N, Haissaguerre M, et al: Radiofrequency catheter ablation of atrial tachycardias. Am Heart J 1996; 131: 481 – 489.en_US
dc.identifier.citedreferenceSalarro JA, Stori C, DeParrti R, et al: Role of the unipolar signal in identification of the target for radiofrequency catheter ablation of permanent ectopic atrial tachycardia (Abstract). PACE 1996; 19: 413.en_US
dc.identifier.citedreferenceGrimm W, Miller J, Josephson ME: Successful and unsuccessful sites of radiofrequency catheter ablation of accessory atrioventricular connections. Am Heart J 1994; 128: 77 – 87.en_US
dc.identifier.citedreferenceMagnin-Poull I, deChillou C, Sadoul N, et al: Valeur del'enregistrement unipolaire et bipolarire dansl'ablation par radiofrequnce des faisceaux accessoires auriculo-ventricularires. Arch Mal Coeur Vaiss 1996; 89: 1177 – 1183.en_US
dc.identifier.citedreferenceSimmers TA, Hauer R, Wever E, et al: Unipolar electrogram models for prediction of outcome in radiofrequency ablation of accessory pathways. PACE 1994; 17: 186 – 199.en_US
dc.identifier.citedreferenceSimmers TA, Peeters HA, Wittkampf FH, et al: Effect of electrode-target distance on dv/dt of initially negative unipolar electrograms: Implications for RF ablation (Abstract). PACE 1996; 19: 23.en_US
dc.identifier.citedreferencedeBakker JMT, Hauer RNW, Simmers TA: Activation mapping: Unipolar versus bipolar recording. In Zipes DP, Jaliffe J eds: Cardiac Electrophysiology: From Cell to Bedside. WB Saunders Co., Philadelphia, 1995, pp. 1068 – 1078.en_US
dc.identifier.citedreferenceSpach MS, Bair RC, Serwer GA: Extracellular potentials related to intracellular action potentials in the dog Purkinje system. Circ Res 1972; 30: 505.en_US
dc.identifier.citedreferenceSpach MS, Miller WT, Miller-Jones E, et al: Extracellular potentials related lo intracellular action potentials during impulse conduction in anisotropic canine cardiac muscle. Circ Res 1979; 45: 188 – 204.en_US
dc.identifier.citedreferenceCalkins H, Kalbfleisch SJ, El-Atassi R, et al: Relation between efficacy of radiofrequency catheter ablation and site of origin of idiopathic ventricular tachycardia. Am J Cardiol 1993; 71: 827 – 833.en_US
dc.identifier.citedreferenceCoggins DL, Lee RJ, Sweeney J, et al: Radiofrequency catheter ablation as a cure for idiopathic tachycardia of both left and right ventricular origin. J Am Coll Cardiol 1994; 23: 1333 – 1341.en_US
dc.identifier.citedreferenceMan KC, Chan K, Daoud E, et al: Spatial resolution of unipolar mapping of the earliest site of ventricular activation (Abstract). PACE 1995; 18: 289.en_US
dc.identifier.citedreferenceTaccardi B, Arisi G, Macchi E, et al. A new intracavitary probe for detecting the site of origin of ectopic ventricular beats during one cardiac cycle. Circulation 1987; 75: 272 – 281.en_US
dc.identifier.citedreferenceKhoury D, Taccardi B, Lux R, et al: Reconstruction of endocardial potentials and activation sequences from intracavitary probe measurements: Localization of pacing sites and effects of myocardial structure. Circulation 1995; 91: 845 – 863.en_US
dc.identifier.citedreferenceKadish AH, Childs K, Schmaltz S, et al: Differences in QRS configuration during unipolar pacing from adjacent sites: Implications for the spatial resolution of pace-mapping. J Am Coll Cardiol 1991; 17: 143 – 151.en_US
dc.identifier.citedreferenceKadish AH, Schmaltz S, Morady F: A comparison of QRS complexes resulting from unipolar and bipolar pacing: Implications for pace-mapping. PACE 1991; 14: 823 – 832.en_US
dc.identifier.citedreferenceLangberg JJ, Gallagher M, Strickberger SA, et al: Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993; 88: 245 – 249.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.