Inducibility of Atrial Fibrillation Before and After Radiofrequency Catheter Ablation of Accessory Atrioventricular Connections
dc.contributor.author | Kalbfleisch, Steven J. | en_US |
dc.contributor.author | El-Atassi, Rafel | en_US |
dc.contributor.author | Calkins, Hugh G. | en_US |
dc.contributor.author | Langberg, Jonathan J. | en_US |
dc.contributor.author | Morady, Fred | en_US |
dc.date.accessioned | 2010-06-01T21:29:18Z | |
dc.date.available | 2010-06-01T21:29:18Z | |
dc.date.issued | 1993-10 | en_US |
dc.identifier.citation | KALBFLEISCH, STEVEN J.; El-ATASSI, RAFEL; CALKINS, HUGH; LANGBERG, JONATHAN J.; MORADY, FRED (1993). "Inducibility of Atrial Fibrillation Before and After Radiofrequency Catheter Ablation of Accessory Atrioventricular Connections." Journal of Cardiovascular Electrophysiology 4(5): 499-503. <http://hdl.handle.net/2027.42/74545> | en_US |
dc.identifier.issn | 1045-3873 | en_US |
dc.identifier.issn | 1540-8167 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/74545 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=8269316&dopt=citation | en_US |
dc.format.extent | 1915372 bytes | |
dc.format.extent | 3109 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.publisher | Blackwell Publishing Ltd | en_US |
dc.rights | 1993 Futura Publishing Company, Inc. | en_US |
dc.subject.other | Atrial Fibrillation | en_US |
dc.subject.other | Wolff-Parkinson-White Syndrome | en_US |
dc.subject.other | Radiofrequency Catheter Ablation | en_US |
dc.title | Inducibility of Atrial Fibrillation Before and After Radiofrequency Catheter Ablation of Accessory Atrioventricular Connections | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | en_US |
dc.subject.hlbsecondlevel | Physiology | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Division of Cardiology, department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan | en_US |
dc.identifier.pmid | 8269316 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/74545/1/j.1540-8167.1993.tb01238.x.pdf | |
dc.identifier.doi | 10.1111/j.1540-8167.1993.tb01238.x | en_US |
dc.identifier.source | Journal of Cardiovascular Electrophysiology | en_US |
dc.identifier.citedreference | Shamia A, Klein G, Guiraudon G, et al: Atrial tibrillation in patients with Wolff-Parkinson-White syndrome: Incidence after surgical ablation of the accessory pathway. Circulation 1985; 1: 161 – 169. | en_US |
dc.identifier.citedreference | Haissaguerre M, Fischer B, Labbe T, et al: Frequency ofrecurrent atrial fibrillation after catheier ablation of overtaccessory pathways. Am J Cardiol 1991; 69: 493 – 497. | en_US |
dc.identifier.citedreference | Roark S, Mc Carthy E, Lee K, et al: Observations onthe occurrence of atrial fibrillation in paroxysmalsupraventricular tachycardia. Am J Cardiol 1986; 57: 571 – 575. | en_US |
dc.identifier.citedreference | Josepheson ME: Clinical Cardiac Electrophysiology:Techniques and Interpretations. Lea & Febiger, Philadelphia, 1993. | en_US |
dc.identifier.citedreference | Wells JL, Karp RB, Kouchoukos NT, et al: Characterization of atrial fibrillation in man: Studies followingopen heart surgery. PACE 1978; 1: 426 – 438. | en_US |
dc.identifier.citedreference | Wells JL, MacLean WAH, James TN, et al: Characterization of atrial flutter: Studies in man after open heartsurgery using fixed alrial electrodes. Circulation 1979; 60: 3: 665 – 673. | en_US |
dc.identifier.citedreference | Calkins H, Langberg J, Sousa J, et al: Radiofrequencycatheter ablation of accessory atrioventricular connections in 250 patients: Abbreviated therapeutic approach to Wolff-Parkinson-White syndrome. Circulation 1992; 85: 1337 – 1346. | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.