Show simple item record

Identification of Ventricular Tachycardia Using Intracavitary Ventricular Electrograms: Analysis of Time and Frequency Domain Patterns

dc.contributor.authorLin, Dongpingen_US
dc.contributor.authorDicarlo, Lorenzo A.en_US
dc.contributor.authorJenkins, Janice M.en_US
dc.date.accessioned2010-06-01T21:55:40Z
dc.date.available2010-06-01T21:55:40Z
dc.date.issued1988-11en_US
dc.identifier.citationLIN, DONGPING; DICARLO, LORENZO A.; JENKINS, JANICE M. (1988). "Identification of Ventricular Tachycardia Using Intracavitary Ventricular Electrograms: Analysis of Time and Frequency Domain Patterns." Pacing and Clinical Electrophysiology 11(11): 1592-1606. <http://hdl.handle.net/2027.42/74961>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/74961
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=2462245&dopt=citationen_US
dc.format.extent6262073 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1988 Official Journal of the International Cardiac Pacing and Electrophysiology Societyen_US
dc.subject.otherVentricular Tachycardiaen_US
dc.subject.otherComputer Analysisen_US
dc.subject.otherVentricular Electrogramsen_US
dc.subject.otherWaveform Analysisen_US
dc.subject.otherMorphologyen_US
dc.titleIdentification of Ventricular Tachycardia Using Intracavitary Ventricular Electrograms: Analysis of Time and Frequency Domain Patternsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationum* St. Joseph Mercy Hospital of the Catherine McAuley Health Center and the School of Medicine, University of Michigan, Ann Arbor, MI USAen_US
dc.contributor.affiliationotherDepartment of Electrical Engineering and Computer Science, School of Engineering, Ann Arbor, MI USAen_US
dc.identifier.pmid2462245en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/74961/1/j.1540-8159.1988.tb06279.x.pdf
dc.identifier.doi10.1111/j.1540-8159.1988.tb06279.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceSowton E. Clinical results with the tachylog antitachycardia pacemaker. PACE 1984; 7: 1313 – 1317.en_US
dc.identifier.citedreferenceCharos GS, Haffajee CI, Gold RL, et al. A theoretically and practically more effective method for interruption of ventricular tachycardia: Self-adapting autodecremental overdrive pacing, Circ 1986; 73: 2: 309 – 315.en_US
dc.identifier.citedreferenceReddy CP, Todd EP, Kuo CS, et al. Treatment of ventricular tachycardia using an automatic scanning extrastimulus pacemaker. J Am Coll Cardiol 1984; 3: 1: 225 – 230.en_US
dc.identifier.citedreferenceSpurrell RAJ, Nathan AW, Camm AI. Clinical experience with implantable scanning tachycardia reversion pacemakers. PACE 1984; 7: 1296 – 1300.en_US
dc.identifier.citedreferenceHiggins IR, Swartz JG, Dehmer GJ, et al. Automatic scanning extrastimulus pacemaker to treat ventricular tachycardia. PACE 1985; 8: 101 – 109.en_US
dc.identifier.citedreferenceOlson WH, Bardy GH, Mehra R, et al. Tachyarrhythmia detection algorithm for an implantable cardioverter and defibrillator. ( abstract ) Circulation 1986; 74: 11 – 110.en_US
dc.identifier.citedreferenceBella PD, Brugada P, Dugernier T, et al. Transventricular lead system for identification and termination of tachycardias, ( abstract ) Circulation 1986; 74: 11 – 183.en_US
dc.identifier.citedreferenceDavies DW, Wainwright RJ, Tooley MA, et al. Detection of pathological tachycardia by analysis of electrogram morphology. PACE 1986; 9: 200 – 208.en_US
dc.identifier.citedreferenceDavies DW, Wainwright RJ, Tooley MA, et al. Endocardial electrogram analysis for the automatic recognition of ventricular tachycardia. ( abstract ) Circulation 1985; 72: 111 – 474.en_US
dc.identifier.citedreferenceMirowski M, Mower MM, Reid PR, et al. The Automatic Implantable Defibrillator. New modality for treatment of life-threatening ventricular arrhythmias. PACE 1982; 384 – 401.en_US
dc.identifier.citedreferenceLangberg JJ, Griffin JC. Arrhythmia identification using the morphology of the endocardial electrogram. ( abstract ) Circulation 1985; 72: III: 474.en_US
dc.identifier.citedreferenceGriffin JC, Nielsen AP, Finke WL, et al. A new method of rhythm identification: Endocardial electrogram morphology. ( abstract ) Circulation 1984; 70: 11 – 201.en_US
dc.identifier.citedreferenceMercando A, Gabry M, Klementowicz P. et al. Detection of ectopy by measurement of ventricular activation sequence using two electrodes. ( abstract ) J Am Coll Cardiol 1986; 7: 2: 184A.en_US
dc.identifier.citedreferenceFahraeus T, Lassvik C, Sonnhag G. Tachycardias initiated by automatic antitachycardia pace makers. PACE 1984; 7: 1049 – 1054.en_US
dc.identifier.citedreferenceMirowski M, Reid PR. Mower MM, et al. Clinical performance of the implantable cardioverter-defibrillator. PACE 1984; 7: 1345 – 1350.en_US
dc.identifier.citedreferenceFeldman CL, Amazeen PG, Klein MD, et al. Computer detection of ventricular ectopic beats. Comp Biomed Res 1970; 3: 666 – 674.en_US
dc.identifier.citedreferenceArzbaecher R, Biancalana P, Stibolt T, et al. Computer technique for detection of cardiac arrhythmias. J Assoc Adv Med Instr 1971; 5: 104.en_US
dc.identifier.citedreferenceJenkins IM, Wu D, Arzbaecher RC. Computer diagnosis of supraventricular and ventricular arrhythmias. Circulation 1979; 60: 977 – 987.en_US
dc.identifier.citedreferenceLin D, Jenkins JM, DiCarlo LA. Analysis of P-wave changes on the esophageal electrogram: A two- lead arrhythmia analysis system using morphology and timing of both atrial and ventricular activation. Comp Cardiol 1987 ( in press ).en_US
dc.identifier.citedreferenceLin D, Jenkins JW, Wiesmeyer MD, et al. Analysis of time and frequency domain patterns of endocardial electrograms to distinguish ventricular tachycardia from sinus rhythm. Comp Cardiol 1986; 171 – 174.en_US
dc.identifier.citedreferenceMorady F, Dicarlo L, Winston S, et al. A prospective comparison of triple extrastimuli and left ventricular stimulation in studies of ventricular tachycardia induction. Circulation 1984; 70: 1: 52 – 57.en_US
dc.identifier.citedreferenceMarriott HJL. Bundle branch block. In: Practical Electrocardiography. Seventh edition. Baltimore/London; Williams & Wilkins, 1983 p. 62 – 83.en_US
dc.identifier.citedreferenceBlum JR, Rosenblatt JI. Probability and Statistics. Philadelphia, W.B. Saunders Co., 1972 p. 193.en_US
dc.identifier.citedreferenceOppenhiem AV, Schafer RW. Digital Signal Processing. Englewood Cliffs, NJ, Prentice-Hall Inc. 1975 p. 242.en_US
dc.identifier.citedreferenceHsia PW, Jenkins JM, Shimoni Y, et al. An automated system for ST segment and arrhythmia analysis in exercise radionuclide ventriculography. IEEE Trans Biomed Eng 1986; 33: 6: 585 – 593.en_US
dc.identifier.citedreferenceArzbaecher R, Bump T, Jenkins JM, et al. Automatic tachycardia recognition, PACE 1984; 7: 541 – 547.en_US
dc.identifier.citedreferenceJenkins JM, Bump T, Munkenbeck F, et al. Tachycardia detection in implantable antitachycardia devices, PACE 1984; 7: 1273 – 1277.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.