Show simple item record

Comparison of Endocardial Activation Times at Effective and Ineffective Ablation Sites Within the Pulmonary Veins

dc.contributor.authorTse, Hung-Faten_US
dc.contributor.authorLau, Chu-Paken_US
dc.contributor.authorKou, William H.en_US
dc.contributor.authorPflosi, Franken_US
dc.contributor.authorOral, Hakanen_US
dc.contributor.authorKim, Michael H.en_US
dc.contributor.authorMichaud, Gregory F.en_US
dc.contributor.authorKnight, Bradley P.en_US
dc.contributor.authorMoscucci, Mauroen_US
dc.contributor.authorStrickberger, S. Adamen_US
dc.contributor.authorMorady, Freden_US
dc.date.accessioned2010-06-01T22:35:40Z
dc.date.available2010-06-01T22:35:40Z
dc.date.issued2000-02en_US
dc.identifier.citationTSE, HUNG-FAT; LAU, CHU-PAK; KOU, WILLIAM; PFLOSI, FRANK; ORAL, HAKAN; KIM, MICHAEL; MICHAUD, GREGORY F.; KNIGHT, BRADLEY P.; MOSCUCCI, MAURO; STRICKBERGER, S. ADAM; MORADY, FRED (2000). "Comparison of Endocardial Activation Times at Effective and Ineffective Ablation Sites Within the Pulmonary Veins." Journal of Cardiovascular Electrophysiology 11(2): 155-159. <http://hdl.handle.net/2027.42/75572>en_US
dc.identifier.issn1045-3873en_US
dc.identifier.issn1540-8167en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/75572
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=10709709&dopt=citationen_US
dc.format.extent2506262 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights2000 Blackwell Publishing Ltden_US
dc.subject.otherPulmonary Veinen_US
dc.subject.otherAtrial Fibrillationen_US
dc.subject.otherRadiofrequency Ablationen_US
dc.subject.otherMappingen_US
dc.titleComparison of Endocardial Activation Times at Effective and Ineffective Ablation Sites Within the Pulmonary Veinsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelInternal Medicine and Specialtiesen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationum* Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michiganen_US
dc.contributor.affiliationotherDivision of Cardiology, Department of Medicine, University of Hong Kong, Queen Mary Hospital, Hong Kongen_US
dc.identifier.pmid10709709en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/75572/1/j.1540-8167.2000.tb00314.x.pdf
dc.identifier.doi10.1111/j.1540-8167.2000.tb00314.xen_US
dc.identifier.sourceJournal of Cardiovascular Electrophysiologyen_US
dc.identifier.citedreferenceJaÏs P, HaÏssaguerre M, Shah DC, et al: A focal source of atrial fibrillation treated by discrete radiofrequency ablation. Circulation 1997; 95: 572 – 576.en_US
dc.identifier.citedreferenceHaÏssaguerre M, JaÏs P, Shah DC, et al: Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659 – 666.en_US
dc.identifier.citedreferenceLau CP, Tse HF, Ayers CM: Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus. J Am Coll Cardiol 1999; 33; 1217 – 1226.en_US
dc.identifier.citedreferenceHsieh MH, Chen SA, Tai CT, et al: Double multielectrotie mapping catheters facilitate radiofrequency catheter ablation of focal atrial fibrillation originating from pulmonary veins. J Cardiovasc Electrophysiol 1999; 10: 136 – 144.en_US
dc.identifier.citedreferenceLok NS, Lau CP, Ho DSW, et al: Hemodynamic effects and clinical determinants of defibrillation threshold for low energy transvenous atrial defibrillation in patients with chronic atrial fibrillation. PACE 1997; 20: 899 – 908.en_US
dc.identifier.citedreferenceDe Almeida OA, Bohm GM, De Paula Carvalho M, et al: The cardiac muscle in the pulmonary vein of rat: A morphological and electrophysiologlcal study. J Morph 1975; 135: 409 – 434.en_US
dc.identifier.citedreferenceCheung DW: Electrical activity of the pulmonary vein and its interaction with the right atrium In the guinea-pig. J Physical 1981; 314: 445 – 456.en_US
dc.identifier.citedreferenceZipes DP, Knope RF: Electrical properties of the thoracic vein. Am J Cardiol 1972; 29: 372 – 376.en_US
dc.identifier.citedreferenceSpach MS, Barr RC, Jewett PH: Spread of excitation from the atrium into thoracic veins in human beings and dogs. Am J Cardiol 1972; 30: 844 – 854.en_US
dc.identifier.citedreferenceNathan H, Eliakim M: The junction between the left atrium and the pulmonary veins: An anatomic study of human hearts. Circulation 1966; 34: 412 – 422.en_US
dc.identifier.citedreferenceIto M, Arita M, Saeki K, et al: Functional properties of sinocaval conduction. Jpn J Physical 1967; 17: 174 – 189.en_US
dc.identifier.citedreferenceSchwartzman D: Circumferential radiofrequency ablation of pulmonary vein orifices: Feasibility of a new technique. (Abstract) PACE 1999; 22: 711.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.