Now showing items 1-2 of 2
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
(Elsevier, 1983)
Experimental determination of the elastic modulus and ultimate strength of human tibial trabecular bone as a function of metaphyseal location is presented.A 1 cm cubic matrix with planes parallel to the subchondral plate ...
Fatigue failure of cortical bone screws
(Elsevier, 1983)
An experimental study of the fatigue life of cortical bone screws under conditions which simulated in vivo usage was performed. The two most important factors influencing fatigue life were axial screw tension (the force ...