Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using
dc.contributor.author | Kozai, Takashi Daniel Yoshida | en_US |
dc.contributor.author | Marzullo, Timothy C. | en_US |
dc.contributor.author | Hooi, F. | en_US |
dc.contributor.author | Langhals, Nicholas Brandon | en_US |
dc.contributor.author | Majewska, A. K. | en_US |
dc.contributor.author | Brown, E. B. | en_US |
dc.contributor.author | Kipke, Daryl R. | en_US |
dc.date.accessioned | 2011-08-10T13:52:52Z | |
dc.date.available | 2011-08-10T13:52:52Z | |
dc.date.issued | 2010-08 | en_US |
dc.identifier.citation | Kozai, T. D. Y.; Marzullo, T. C.; Hooi, F.; Langhals, N. B.; Majewska, A. K.; Brown, E. B.; Kipke, D. R. (2010). "Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using." Journal of Neural Engineering, 7(4): 046011. <http://hdl.handle.net/2027.42/85401> | en_US |
dc.identifier.issn | 1741-2560 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/85401 | |
dc.description.abstract | Penetrating neural probe technologies allow investigators to record electrical signals in the brain. The implantation of probes causes acute tissue damage, partially due to vasculature disruption during probe implantation. This trauma can cause abnormal electrophysiological responses and temporary increases in neurotransmitter levels, and perpetuate chronic immune responses. A significant challenge for investigators is to examine neurovascular features below the surface of the brain in vivo. The objective of this study was to investigate localized bleeding resulting from inserting microscale neural probes into the cortex using two-photon microscopy (TPM) and to explore an approach to minimize blood vessel disruption through insertion methods and probe design. 3D TPM images of cortical neurovasculature were obtained from mice and used to select preferred insertion positions for probe insertion to reduce neurovasculature damage. There was an 82.8 ± 14.3% reduction in neurovascular damage for probes inserted in regions devoid of major (>5 µm) sub-surface vessels. Also, the deviation of surface vessels from the vector normal to the surface as a function of depth and vessel diameter was measured and characterized. 68% of the major vessels were found to deviate less than 49 µm from their surface origin up to a depth of 500 µm. Inserting probes more than 49 µm from major surface vessels can reduce the chances of severing major sub-surface neurovasculature without using TPM. | en_US |
dc.title | Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.identifier.pmid | 20644246 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/85401/1/7_4_046011.pdf | |
dc.identifier.doi | 10.1088/1741-2560/7/4 | en_US |
dc.identifier.source | Journal of Neural Engineering | en_US |
dc.owningcollname | Physics, Department of |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.