Show simple item record

Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging

dc.contributor.authorWang, Yien_US
dc.contributor.authorEl-Mohri, Youcefen_US
dc.contributor.authorAntonuk, Larry E.en_US
dc.contributor.authorZhao, Qihuaen_US
dc.date.accessioned2011-08-10T13:52:56Z
dc.date.available2011-08-10T13:52:56Z
dc.date.issued2010-07en_US
dc.identifier.citationWang, Yi; El-Mohri, Youcef; Antonuk, Larry E.; Zhao, Qihua (2010). "Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging." Physics in Medicine and Biology, 55(13): 3659. <http://hdl.handle.net/2027.42/85404>en_US
dc.identifier.issn0031-9155en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85404
dc.description.abstractThe use of thick, segmented scintillators in electronic portal imagers offers the potential for significant improvement in x-ray detection efficiency compared to conventional phosphor screens. Such improvement substantially increases the detective quantum efficiency (DQE), leading to the possibility of achieving soft-tissue visualization at clinically practical (i.e. low) doses using megavoltage (MV) cone-beam computed tomography. While these DQE increases are greatest at zero spatial frequency, they are diminished at higher frequencies as a result of degradation of spatial resolution due to lateral spreading of secondary radiation within the scintillator—an effect that is more pronounced for thicker scintillators. The extent of this spreading is even more accentuated for radiation impinging the scintillator at oblique angles of incidence due to beam divergence. In this paper, Monte Carlo simulations of radiation transport, performed to investigate and quantify the effects of beam divergence on the imaging performance of MV imagers based on two promising scintillators (BGO and CsI:Tl), are reported. In these studies, 10–40 mm thick scintillators, incorporating low-density polymer, or high-density tungsten septal walls, were examined for incident angles corresponding to that encountered at locations up to ~15 cm from the central beam axis (for an imager located 130 cm from a radiotherapy x-ray source). The simulations demonstrate progressively more severe spatial resolution degradation (quantified in terms of the effect on the modulation transfer function) as a function of increasing angle of incidence (as well as of the scintillator thickness). Since the noise power behavior was found to be largely independent of the incident angle, the dependence of the DQE on the incident angle is therefore primarily determined by the spatial resolution. The observed DQE degradation suggests that 10 mm thick scintillators are not strongly affected by beam divergence for detector areas up to ~30 × 30 cm2. For thicker scintillators, the area that is relatively unaffected is significantly reduced, requiring a focused scintillator geometry in order to preserve spatial resolution, and thus DQE.en_US
dc.titleMonte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imagingen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysicsen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.peerreviewedPeer Revieweden_US
dc.identifier.pmid20526032en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85404/1/pmb10_13_006.pdf
dc.identifier.doi10.1088/0031-9155/55/13/006en_US
dc.identifier.sourcePhysics in Medicine and Biologyen_US
dc.owningcollnamePhysics, Department of


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.