The ATLAS MDT remote calibration centers
dc.contributor.author | Dai, T. S. | en_US |
dc.contributor.author | Salvo, A. De | en_US |
dc.contributor.author | Diehl, E. | en_US |
dc.contributor.author | Mattia, A. Di | en_US |
dc.contributor.author | Kennedy, J. | en_US |
dc.contributor.author | McKee, S. | en_US |
dc.contributor.author | Orestano, D. | en_US |
dc.contributor.author | Pasqualucci, E. | en_US |
dc.contributor.author | Petrucci, F. | en_US |
dc.contributor.author | Rauscher, F. | en_US |
dc.contributor.author | Serfon, C. | en_US |
dc.contributor.author | Vandelli, W. | en_US |
dc.date.accessioned | 2011-08-10T13:53:25Z | |
dc.date.available | 2011-08-10T13:53:25Z | |
dc.date.issued | 2010-04 | en_US |
dc.identifier.citation | Dai, T.; Salvo, A. De; Diehl, E.; Mattia, A. Di; Kennedy, J.; McKee, S.; Orestano, D.; Pasqualucci, E.; Petrucci, F.; Rauscher, F.; Serfon, C.; Vandelli, W. (2010). "The ATLAS MDT remote calibration centers." Journal of Physics: Conference Series, 219(2): 022028. <http://hdl.handle.net/2027.42/85421> | en_US |
dc.identifier.issn | 1742-6596 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/85421 | |
dc.description.abstract | The precision chambers of the ATLAS Muon Spectrometer are built with Monitored Drift Tubes (MDT). The requirement of high accuracy and low systematic error, to achieve a transverse momentum resolution of 10% at 1 TeV, can only be accomplished if the calibrations are known with an accuracy of 20 μm. The relation between the drift path and the measured time (the socalled r-t relation) depends on many parameters (temperature T, hit rate, gas composition, thresholds,...) subject to time variations. The r-t relation has to be measured from the data without the use of an external detector, using the autocalibration technique. This method relies on an iterative procedure applied to the same data sample, starting from a preliminary set of constants. The required precision can be achieved using a large (few thousand) number of non-parallel tracks crossing a region, called calibration region, i.e. the region of the MDT chamber sharing the same r-t relation. | en_US |
dc.title | The ATLAS MDT remote calibration centers | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/85421/1/jpconf10_219_022028.pdf | |
dc.identifier.doi | 10.1088/1742-6596/219/2/022028 | en_US |
dc.identifier.source | Journal of Physics: Conference Series | en_US |
dc.owningcollname | Physics, Department of |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.