Show simple item record

Intensity-Based Image Registration Using Robust Correlation Coefficients

dc.contributor.authorKim, Jeongtaeen_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.date.accessioned2011-08-18T18:20:44Z
dc.date.available2011-08-18T18:20:44Z
dc.date.issued2004-11-01en_US
dc.identifier.citationKim, J.; Fessler, J.A. (2004). "Intensity-Based Image Registration Using Robust Correlation Coefficients." IEEE Transactions on Medical Imaging 23(11): 1430-1444. <http://hdl.handle.net/2027.42/85801>en_US
dc.identifier.issn0278-0062en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85801
dc.description.abstractThe ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of “outlier” objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can lead to biased registrations. This paper describes an intensity-based image registration technique that uses a robust correlation coefficient as a similarity measure. Relative to the ordinary sample correlation coefficient, the proposed similarity measure reduces the influence of outliers. We also compared the performance of the proposed method with the mutual information- based method. The robust correlation-based method should be useful for image registration in radiotherapy (KeV to MeV X-ray images) and image-guided surgery applications. We have investigated the properties of the proposed method by theoretical analysis, computer simulations, a phantom experiment, and with functional magnetic resonance imaging data.en_US
dc.publisherIEEEen_US
dc.titleIntensity-Based Image Registration Using Robust Correlation Coefficientsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationotherInformation Electronics Department, EwhaWomans University, Seoul 120-750, South Korea.en_US
dc.identifier.pmid15554130en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85801/1/Fessler55.pdf
dc.identifier.doi10.1109/TMI.2004.835313en_US
dc.identifier.sourceIEEE Transactions on Medical Imagingen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.