Show simple item record

List-Mode Maximum Likelihood Reconstruction of Compton Scatter Camera Images in Nuclear Medicine

dc.contributor.authorWilderman, Scott J.en_US
dc.contributor.authorClinthorne, Neal H.en_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.contributor.authorRogers, W. Lesen_US
dc.date.accessioned2011-08-18T18:20:47Z
dc.date.available2011-08-18T18:20:47Z
dc.date.issued1998-11-08en_US
dc.identifier.citationWilderman, S.J.; Clinthorne, N.H.; Fessler, J.A.; Rogers, W.L. (1998). "List-Mode Maximum Likelihood Reconstruction of Compton Scatter Camera Images in Nuclear Medicine." IEEE Conference Record of Nuclear Science Symposium 3: 1716-1720. <http://hdl.handle.net/2027.42/85815>en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85815
dc.description.abstractA Maximum Likelihood (ML) image reconstruction technique using list-mode data has been applied to Compton scattering camera imaging. List-mode methods are appealing in Compton camera image reconstruction because the total number of data elements in the list (the number of detected photons) is significantly smaller than the number of possible combinations of position and energy measurements, leading to a much smaller problem than that faced by traditional iterative reconstruction techniques. For a realistic size device, the number of possible detector bins can be as large as 10 billion per pixel of the image space, while the number of counted photons would typically be a very small fraction of that. The primary difficulty in applying the list-mode technique is in determining the parameters which describe the response of the imaging system. In this work, a simple method for determining the required system matrix coefficients is employed, in which a back-projection is performed in list-mode, and response coefficients determined for only tallied pixels. Projection data has been generated for a representative Compton camera system by Monte Carlo simulation for disk sources with hot and cold spots and energies of 141, 364, and 511 keV, and reconstructions performed.en_US
dc.publisherIEEEen_US
dc.titleList-Mode Maximum Likelihood Reconstruction of Compton Scatter Camera Images in Nuclear Medicineen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.identifier.pmid9591845en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85815/1/Fessler155.pdf
dc.identifier.doi10.1109/NSSMIC.1998.773871en_US
dc.identifier.sourceIEEE Conference Record of Nuclear Science Symposiumen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.