Show simple item record

Near-Optimal Signal Detection for Finite-State Markov Signals with Application to Magnetic Resonance Force Microscopy

dc.contributor.authorTing, M.en_US
dc.contributor.authorHero, Alfred O. IIIen_US
dc.contributor.authorRugar, Danielen_US
dc.contributor.authorChun-Yu Yipen_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.date.accessioned2011-08-18T18:20:50Z
dc.date.available2011-08-18T18:20:50Z
dc.date.issued2006-06-05en_US
dc.identifier.citationTing, M.; Hero, A.O., III; Rugar, D.; Chun-Yu Yip; Fessler, J.A. (2006). "Near-Optimal Signal Detection for Finite-State Markov Signals with Application to Magnetic Resonance Force Microscopy."IEEE Transactions on Signal Processing 54(6): 2049-2062. <http://hdl.handle.net/2027.42/85833>en_US
dc.identifier.issn1053-587Xen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85833
dc.description.abstractDetection of a finite-state Markov signal in additive white Gaussian noise (AWGN) can be done in an intuitive manner by applying an appropriate filter and using an energy detector. One might not expect this heuristic approach to signal detection to be optimal. However, in this paper, we show that for a certain type of finite-state Markov signal, namely, the discrete-time (DT) random telegraph, this filtered energy detector is approximately optimal under the following conditions of: symmetric transition probabilities, low signal-to-noise ratio (SNR), long observation time, and small probability of transition between two consecutive time instances. When these last three conditions hold, but the transition probabilities are not symmetric, we show that a variant of the filtered energy detector is approximately optimal. It is also shown, under low SNR conditions, that the likelihood ratio test (LRT) for a finite-state DT Markov signal in AWGN reduces to the matched filter statistic with the minimum mean-squared-error (MMSE) predictor signal values used in place of the known signal values. Using this result, we propose a general methodology for obtaining an approximation to the LRT of a finite-state DT Markov signal in AWGN. Specifically, instead of the conditional mean (also MMSE) estimators, affine estimators with lowest mean squared error are used. This work is relevant to magnetic resonance force microscopy, an emerging technology that uses ultrasensitive force sensing to detect magnetic resonance. Sensitivity down to the single spin level was demonstrated in a recent experiment.en_US
dc.publisherIEEEen_US
dc.titleNear-Optimal Signal Detection for Finite-State Markov Signals with Application to Magnetic Resonance Force Microscopyen_US
dc.typearticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Electrical Engineering and Computer Science.en_US
dc.contributor.affiliationotherIBM Research Division, Almaden Research Center, San Jose, CA 95120 USA.en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85833/1/Fessler44.pdf
dc.identifier.doi10.1109/TSP.2006.874413en_US
dc.identifier.sourceIEEE Transactions on Signal Processingen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.