Show simple item record

Penalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomography

dc.contributor.authorFessler, Jeffrey A.en_US
dc.date.accessioned2011-08-18T18:20:53Z
dc.date.available2011-08-18T18:20:53Z
dc.date.issued1994-06en_US
dc.identifier.citationFessler, J.A. (1994). "Penalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomography". IEEE Transactions on Medical Imaging 13(2): 290-300. <http://hdl.handle.net/2027.42/85851>en_US
dc.identifier.issn0278-0062en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85851
dc.description.abstractPresents an image reconstruction method for positron-emission tomography (PET) based on a penalized, weighted least-squares (PWLS) objective. For PET measurements that are precorrected for accidental coincidences, the author argues statistically that a least-squares objective function is as appropriate, if not more so, than the popular Poisson likelihood objective. The author proposes a simple data-based method for determining the weights that accounts for attenuation and detector efficiency. A nonnegative successive over-relaxation (+SOR) algorithm converges rapidly to the global minimum of the PWLS objective. Quantitative simulation results demonstrate that the bias/variance tradeoff of the PWLS+SOR method is comparable to the maximum-likelihood expectation-maximization (ML-EM) method (but with fewer iterations), and is improved relative to the conventional filtered backprojection (FBP) method. Qualitative results suggest that the streak artifacts common to the FBP method are nearly eliminated by the PWLS+SOR method, and indicate that the proposed method for weighting the measurements is a significant factor in the improvement over FBP.en_US
dc.publisherIEEEen_US
dc.titlePenalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomographyen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.identifier.pmid18218505en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85851/1/Fessler105.pdf
dc.identifier.doi10.1109/42.293921en_US
dc.identifier.sourceIEEE Transactions on Medical Imagingen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.